The DOI matches its Crossref record.
Inflammatory chemical mediators during conventional ventilation and during high frequency oscillatory ventilation.
Abstract
Inflammatory chemical mediators, platelet-activating factor (PAF), thromboxane (TX) B2, and 6-keto-prostaglandin (PG)F1 alpha, were extracted from lung lavage fluid after conventional mechanical ventilation (CMV) and high frequency oscillatory ventilation (HFOV) to clarify the relation between mode of ventilation and lung injury in surfactant-depleted rabbit lungs. Anesthetized adult rabbits were tracheostomized, and surfactant depletion was induced by repeated saline lavage. Lung lavage for measurement of mediators was performed after 4 h of CMV at an FIO2 of 1.0 and a mean airway pressure of 15 cm H2O or HFOV (15 Hz) at an FIO2 of 1.0 or 0.21 and a mean airway pressure of 15 cm H2O. The number of total cells and polymorphonuclear leukocytes (PMN) and the levels of PAF, TXB2, and 6-keto-PGF1 alpha were measured by radioimmunoassay. Total respiratory compliance (Crs) was measured by the passive flow-volume curve method. The numbers of PMN, and the levels of PAF and TXB2 in lung lavage fluid were significantly greater during CMV than during HFOV. HFOV resulted in decreased production of PAF and TXB2 in a surfactant-depleted rabbit lung. Crs was significantly less during CMV than during HFOV. These results suggest that HFOV could prevent the release of such inflammatory chemical mediators and result in less lung injury than CMV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Ventilator-Induced Lung Injury
Slutsky, A. S., & Ranieri, V. M. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208707 · Cited by 2,211
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330
Multiple System Organ Failure: Is Mechanical Ventilation a Contributing Factor?
SLUTSKY, A. S., & TREMBLAY, L. N. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.6.9709092 · Cited by 836
Lung Injury Caused by Mechanical Ventilation
Slutsky, A. S. (1999) · Chest · doi:10.1378/chest.116.suppl_1.9s-a · Cited by 634
Metadata
- Authors
- Imai, Y., Kawano, T., Miyasaka, K., Takata, M., Imai, T., & Okuyama, K.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-12
- Volume
- 150
- Issue
- 6
- Pages
- 1550-1554
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1983843998
- Cited by
- 206
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inflammatory chemical mediators during conventional ventilation and during high frequency oscillatory ventilation. https://app.cochat.ai/papers/10.1164/ajrccm.150.6.7952613
- The paper
- Imai, Y., Kawano, T., Miyasaka, K., Takata, M., Imai, T., & Okuyama, K. (1994). Inflammatory chemical mediators during conventional ventilation and during high frequency oscillatory ventilation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.150.6.7952613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.