Nasal contribution to exhaled nitric oxide at rest and during breathholding in humans.
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We characterized the nasal contribution to exhaled nitric oxide (NO) at rest and during breathholding in humans. Exhaled NO was greater during nose breathing (141 +/- 17 nl/min/M2, mean +/- SEM) compared with mouth breathing (68 +/- 6 nl/min/M2, n = 8, p < 0.001). After voluntary closure of the soft palate (VCSP) to eliminate nasal NO, exhaled NO from the mouth decreased further (30 +/- 4 nl/min/M2, p < 0.001). Release of NO into nasal passages during VCSP (217 +/- 19 nl/min/M2) was greater than exhaled NO during nasal breathing (141 +/- 17 nl/min/m2, p < 0.001), suggesting that nasal NO is taken up by the respiratory tract. During mouth breathing or nose breathing, NO concentrations sampled with a bronchoscope were higher in the nasopharynx than at the epiglottis or in the trachea in five subjects. Increased peak exhaled NO after a breathhold (33 +/- 7 ppb) was reduced (10 +/- 4 ppb, p < 0.001) after balloon occlusion of the nasopharynx. NO concentration during breathholding increased to a greater extent in the nasopharynx than in the pharynx or trachea. We conclude that the majority of exhaled NO at rest and during a breathhold originates in the nasopharynx.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humans
Gustafsson, L. E., Leone, A. M., Persson, M. G., Wiklund, N. P., & Moncada, S. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91268-h · Cited by 964
Single-breath nitric oxide measurements in asthmatic patients and smokers
Persson, M. G., Gustafsson, L. E., Zetterström, O., Agrenius, V., & Ihre, E. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90935-0 · Cited by 483
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Worlitzsch, D., Tarran, R., Ulrich, M., Schwab, U. E., Cekici, A., Meyer, K. C., Birrer, P., Bellon, G., Berger, J., Weiß, T., et al. (2002) · Journal of Clinical Investigation · doi:10.1172/jci13870 · Cited by 1,099
Worlitzsch, D., Tarran, R., Ulrich, M., Schwab, U., Cekici, A., Meyer, K. C., Birrer, P., Bellon, G., Berger, J., Weiss, T., et al. (2002) · Journal of Clinical Investigation · doi:10.1172/jci0213870 · Cited by 932
(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.6.ats8-99 · Cited by 771
Kharitonov, S., Alving, K., & Barnes, P. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10071683 · Cited by 664
Metadata
- Authors
- Kimberly, B., Nejadnik, B., Giraud, G. D., & Holden, W. E.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-02
- Volume
- 153
- Issue
- 2
- Pages
- 829-836
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1979317956
- Cited by
- 150
- References
- 2
- FWCI
- 36.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nasal contribution to exhaled nitric oxide at rest and during breathholding in humans. https://app.cochat.ai/papers/10.1164/ajrccm.153.2.8564139
- The paper
- Kimberly, B., Nejadnik, B., Giraud, G. D., & Holden, W. E. (1996). Nasal contribution to exhaled nitric oxide at rest and during breathholding in humans. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.153.2.8564139
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.