Abstract

Epidemiologic data indicate that the relationship between obesity and obstructive sleep apnea (OSA) is largely explained by variation in neck size. Fat deposits in the neck may predispose to upper airway (UA) occlusion during sleep by altering the mechanical properties of the UA, particularly at the level of the velopharynx (VP). To determine whether effective compliance (CEFF) of the VP is related to obesity in the neck, we have performed anthropometrics, polysomnography, and dynamic UA videoendoscopy in 18 patients with OSA and eight nonapneic control subjects. Following topical anesthesia (cocaine 4%) to one nasal passage, subjects were examined with a thin fiberscope (outer diameter [OD] 3.8 mm) while awake, supine, breathing exclusively through the nose, during a maximal vital capacity (VC) maneuver against an unoccluded airway. UA cross-sectional area (CSA), anteroposterior (AP) and lateral (L) diameters were measured from stored images. CEFF was expressed as the ratio of CSAVP in expiration (E) to inspiration (I) during the maximal VC maneuver (expiratory CSAMAX/inspiratory CSAMIN), and airway shape as AP/L diameter. The OSA patients were divided into two groups based on median neck circumference (NC). CEFF of the VP was greater in OSA patients compared with control subjects (CEFF 2.0 +/- 0.8 versus 1.1 +/- 0.5; p < 0.001). CEFF was greater in the large NC group compared with both the small NC group (p < 0.05) and control subjects (p < 0.01), but the difference between the small NC group and control subjects was not significant. CEFF was related to NC (r = 0.63; p = 0.001; n = 26), body mass index (r = 0.54; p < 0.01, n = 26), and apnea-hypopnea index (r = 0.43; p < 0.05; n = 23). The change in CSAVP during the maximal VC maneuver was mainly due to inspiratory narrowing. Obese patients with large necks have a more collapsible velopharynx during wakefulness, which may predispose to upper airway obstruction during sleep.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.154.3.8810623

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 71

Metadata

Authors
Ryan, C. F., & Love, L. L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1996-09
Volume
154
Issue
3
Pages
806-812
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2029537424
Cited by
71
References
8
FWCI
2.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical properties of the velopharynx in obese patients with obstructive sleep apnea. https://app.cochat.ai/papers/10.1164/ajrccm.154.3.8810623
The paper
Ryan, C. F., & Love, L. L. (1996). Mechanical properties of the velopharynx in obese patients with obstructive sleep apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.154.3.8810623

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.