Mechanism of short-term improvement in lung function after emphysema resection.
The DOI matches its Crossref record.
Abstract
We prospectively investigated the mechanism of airflow limitation before and after targeted emphysematous resection in 12 consecutively studied adult patients 68 +/- 4 yr of age (mean +/- SD) with very severe COPD undergoing bilateral thoracoscopic stapling techniques. Lung function, static lung elastic recoil, and airway conductance was measured 2 wk before and 5 to 6 mo after surgery. After surgery, there was a significant (p < 0.01) reduction in TLC (9.3 +/- 0.3 [mean +/- SEM] to 7.7 +/- 0.4 L), functional residual capacity, and residual volume. Airway conductance, FVC, and FEV1 (0.7 +/- 0.1 to 1.2 +/- 0.2 L) all improved significantly (p < 0.01). Lung elastic recoil increased markedly at TLC (from 10.3 +/- 0.5 to 14.6 +/- 1.0 cm H20; p < 0.001) as did maximal expiratory airflow in every patient. Analysis of maximal expiratory flow-static elastic recoil pressure curve indicated that conductance of the S segment (Gs) increased from 0.20 +/- 0.03 (mean +/- SEM) to 0.27 +/- 0.03 L/s/cm H20 (p < 0.01), and the critical transmural pressure (Ptm') decreased from 3.1 +/- 0.2 to 2.4 +/- 0.2 cm H20 (p < 0.02). Mean airway conductance increased from 0.14 to 0.22 L/s/cm H20 (p < 0.01). The improvement in maximal expiratory airflow can be primarily attributed to increased lung elastic recoil and its secondary effect on enlarging airway diameter causing increased airway conductance, increased Gs, and decreased Ptm'.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dyspnea: Mechanisms, Assessment, and Management: A Consensus Statement
(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.ats898 · Cited by 1,052
A Randomized Study of Endobronchial Valves for Advanced Emphysema
Sciurba, F. C., Ernst, A., Herth, F. J. F., Strange, C., Criner, G. J., Marquette, C. H., Kovitz, K. L., Chiacchierini, R. P., Goldin, J., & McLennan, G. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0900928 · Cited by 832
Dyspnea Mechanisms, Assessment and Management: A Consensus Statement
Editorial, A. (2005) · PULMONOLOGIYA · doi:10.18093/0869-0189-2005-0-2-9-36 · Cited by 808
Cooper, J. D., Patterson, G. A., Sundaresan, R. S., Trulock, E. P., Yusen, R. D., Pohl, M. S., & Lefrak, S. S. (1996) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70147-2 · Cited by 518
Ventilatory limitations in chronic obstructive pulmonary disease
O???DONNELL, D. E. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200107001-00002 · Cited by 148
Effect of Lung Volume Reduction Surgery on Neuromechanical Coupling of the Diaphragm
LAGHI, F., JUBRAN, A., TOPELI, A., FAHEY, P. J., GARRITY, E. R., ARCIDI, J. M., de PINTO, D. J., EDWARDS, L. C., & TOBIN, M. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.2.9705082 · Cited by 108
Physiologic Basis for Improved Pulmonary Function after Lung Volume Reduction
Fessler, H. E., Scharf, S. M., Ingenito, E. P., McKenna, R. J., & Sharafkhaneh, A. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-117et · Cited by 84
“However, preoperative measurements of elastic recoil do not reliably predict response after LVRS, and improvement in recoil correlates poorly, if at all, with improvement in FEV1 (13, 16).”
BackgroundSelf-citationMarchand, E., Gayan-Ramirez, G., De Leyn, P., & Decramer, M. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.13368699 · Cited by 51
Metadata
- Authors
- Gelb, A. F., Zamel, N., McKenna, R. J., & Brenner, M.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-10
- Volume
- 154
- Issue
- 4
- Pages
- 945-951
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1981911799
- Cited by
- 126
- References
- 0
- FWCI
- 15.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.