Comparative measurement of lung deposition of inhaled fine particles in normal subjects and patients with obstructive airway disease.
Abstract
Particulate pollutants have been suggested as a risk factor for increase in mortality and morbidity in patients with obstructive airway disease. In the present study we hypothesized that enhanced particle deposition dose is an underlying factor for such a finding. We measured lung deposition in normal healthy control subjects (N; n = 10) and in subjects with varying levels of airway obstruction: smokers (S; n = 10), smokers with small airways disease (SAD; n = 10), asthmatics (A; n = 5), and patients with chronic obstructive airway disease (COPD; n = 10). The subjects inhaled a uniform size sebacate aerosol (1-micron diameter) from a collapsible bag of a known volume (500 ml) repeatedly for as many as 15 breaths at a rate of 30 breaths/min. Aerosol concentration was monitored continuously at the mouth by a laser aerosol photometer. After correcting for particle loss in the bag, lung deposition fraction [DF = (inhaled minus exhaled)/inhaled], was determined breath by breath. DF values (mean +/- SD) were 0.14 +/- 0.02, 0.16 +/- 0.02, 0.21 +/- 0.05, 0.22 +/- 0.02 and 0.028 +/- 0.03 for N, S, SAD, A, and COPD, respectively. DF values in S, SAD, A, and COPD were 16, 49, 59, and 103% greater, respectively, than that of normal subjects (p < 0.05). DF of COPD was also greater than that of SAD or A (p < 0.05). No difference was found between SAD and A. When all of the subject data were combined, DF was correlated well with percent predicted FEV1 and FEF25-75 (r2 = 0.63 in both). The results indicate a marked increase in particle deposition in patients with obstructive lung disease, and this can be an important factor for the development of the adverse health effects of pollutant particles on the one hand and for the treatment of patients with drug aerosols on the other.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Beyond PM2.5: The role of ultrafine particles on adverse health effects of air pollution
Chen, R., Hu, B., Liu, Y., Xu, J., Yang, G., Xu, D., & Chen, C. (2016) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2016.03.019 · Cited by 388
Möller, W., Felten, K., Sommerer, K., Scheuch, G., Meyer, G., Meyer, P., Häussinger, K., & Kreyling, W. G. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200602-301oc · Cited by 364
Ultrafine particle deposition in subjects with asthma.
Chalupa, D. C., Morrow, P. E., Oberdörster, G., Utell, M. J., & Frampton, M. W. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.6851 · Cited by 354
Prevention of Cold Injuries during Exercise
Castellani, J. W., Young, A. J., Ducharme, M. B., Giesbrecht, G. G., Glickman, E., & Sallis, R. E. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000241641.75101.64 · Cited by 350
Metadata
- Authors
- Kim, C. S., & Kang, T. C.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-03
- Volume
- 155
- Issue
- 3
- Pages
- 899-905
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2048254190
- Cited by
- 189
- References
- 0
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative measurement of lung deposition of inhaled fine particles in normal subjects and patients with obstructive airway disease. https://app.cochat.ai/papers/10.1164/ajrccm.155.3.9117024
- The paper
- Kim, C. S., & Kang, T. C. (1997). Comparative measurement of lung deposition of inhaled fine particles in normal subjects and patients with obstructive airway disease. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.155.3.9117024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.