Pulmonary Function Tests and CT Scan in the Management of Idiopathic Pulmonary Fibrosis
The DOI matches its Crossref record.
Abstract
Relationships between pulmonary function testing and high-resolution computed tomography (HRCT) were studied in 39 untreated patients with idiopathic pulmonary fibrosis (IPF) at diagnosis, 23 of whom were followed during 7.5 +/- 0.3 mo (mean +/- SEM). At diagnosis, the extent of overall lung involvement in the HRCT scans showed a moderate but significant correlation only with FVC (r = -0.46, p = 0. 003) and DLCO (r = -0.40, p = 0.03). The extent of ground glass pattern also correlated with FVC (r = -0.58, p = 0.0001). Arterial PO2 at peak exercise (n = 13 patients) showed a significant association with the extent of both ground-glass pattern and overall lung involvement in HRCT (r = -0.60, p = 0.02; and r = -0.64, p = 0. 01, respectively). On multivariate analysis a significant independent correlation between the global disease extent in HRCT and both FVC and DLCO was observed. Changes over time in the total extent of the disease evaluated with HRCT scans were also related to those observed in DLCO and in FVC (r = -0.57, p = 0.01, and r = -0. 51, p = 0.01, respectively). The present study suggests that FVC and DLCO are the physiological variables that best reflect the global extent of disease in IPF and thus may provide significant information for the assessment of the disease's progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
Idiopathic Pulmonary Fibrosis: Diagnosis and Treatment: International Consensus Statement
(2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.ats3-00 · Cited by 2,628
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Gross, T. J., & Hunninghake, G. W. (2001) · New England Journal of Medicine · doi:10.1056/nejmra003200 · Cited by 962
Wells, A. U., Desai, S. R., Rubens, M. B., Goh, N. S. L., Cramer, D., Nicholson, A. G., Colby, T. V., du Bois, R. M., & Hansell, D. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2111053 · Cited by 686
Metadata
- Authors
- XAUBET, A., AGUSTÍ, C., LUBURICH, P., ROCA, J., MONTÓN, C., AYUSO, M. C., BARBERÁ, J. A., & RODRIGUEZ-ROISIN, R.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-08-01
- Volume
- 158
- Issue
- 2
- Pages
- 431-436
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2141162061
- Cited by
- 122
- References
- 0
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary Function Tests and CT Scan in the Management of Idiopathic Pulmonary Fibrosis. https://app.cochat.ai/papers/10.1164/ajrccm.158.2.9709008
- The paper
- XAUBET, A., AGUSTÍ, C., LUBURICH, P., ROCA, J., MONTÓN, C., AYUSO, M. C., BARBERÁ, J. A., & RODRIGUEZ-ROISIN, R. (1998). Pulmonary Function Tests and CT Scan in the Management of Idiopathic Pulmonary Fibrosis. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.158.2.9709008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.