CoChat

Assessment of Inspiratory Flow Limitation Invasively and Noninvasively during Sleep

CLARK, SUSANNE A., WILSON, CHRISTINE R., SATOH, MAKOTO, PEGELOW, DAVID, DEMPSEY, JEROME A. · 1998 · American Journal of Respiratory and Critical Care Medicine
Cited by 108

The DOI matches its Crossref record.

Abstract

To define the standard of airway flow limitation, pharyngeal pressure and flow rate were measured during wakefulness and sleep in seven habitual snorers with widely varying degrees of sleep-induced increases in upper airway resistance. Inspiratory pressure:flow relationships were used to group breaths into four categories of flow limitation, including linear (Level 1), mildly alinear (Level 2), constant flow rate with no pressure dependence (Level 3), and decreasing flow rate throughout significant portions of inspiration, i.e., negative pressure dependence (Level 4). These pressure:flow rate gold standards of flow limitation were used to evaluate a flow limitation index derived from the time profile (or "shape") of three noninvasive estimates of flow rate: (1) pneumotach flow rate, (2) differentiated sum respiratory inductance plethysmography (RIP), and (3) nasal pressure. A nonflow limited template for each of these noninvasive measurements was taken from awake breaths and the difference in area determined between the template breath and each of the noninvasive signals measured during nonrapid eye movement (NREM) sleep. The noninvasive flow limitation indices were found to be effective in differentiating severe types of inspiratory flow limitation, i.e., Level 1 versus Level 3 or Level 4 (sensitivity/specificity > 80%). On the other hand, these indirect indices were not able to consistently detect mild levels of flow limitation (Level 1 versus Level 2; sensitivity/specificity = 62 to 72%); nor were these noninvasive estimates of flow rate "shape" sensitive to breaths with a high but fixed resistance throughout inspiration. The area index derived from measurements of pressure at the nares (Pn) was the most sensitive, nonperturbing, noninvasive measure of flow rate and flow limitation, and we recommend its use for recognizing most of the common types of moderate to severe levels of airway flow limitation in sleeping subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.158.3.9708056

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 108

Metadata

Authors
CLARK, S. A., WILSON, C. R., SATOH, M., PEGELOW, D., & DEMPSEY, J. A.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1998-09-01
Volume
158
Issue
3
Pages
713-722
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2058263723
Cited by
108
References
0
FWCI
3.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Inspiratory Flow Limitation Invasively and Noninvasively during Sleep. https://app.cochat.ai/papers/10.1164/ajrccm.158.3.9708056
The paper
CLARK, S. A., WILSON, C. R., SATOH, M., PEGELOW, D., & DEMPSEY, J. A. (1998). Assessment of Inspiratory Flow Limitation Invasively and Noninvasively during Sleep. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.158.3.9708056

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.