CoChat

Instability of Ventilatory Control in Patients with Obstructive Sleep Apnea

HUDGEL, DAVID W., GORDON, ELIZABETH A., THANAKITCHARU, SITTHEP, BRUCE, EUGENE N. · 1998 · American Journal of Respiratory and Critical Care Medicine

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Because of the oscillatory pattern of upper airway resistance and breathing during sleep in patients with obstructive sleep apnea (OSA), we hypothesized that OSA patients have an underlying instability of ventilatory drive to inspiratory muscles. To assess the stability of ventilatory drive in OSA patients and controls, we used the pseudorandom binary stimulation (PRBS) test and examined the closed- and open-loop responses to hyperoxic hypercapnia. The closed-loop response is produced by interactions of dynamic gain in controller, plant, and ventilatory feedback. The open-loop response reflects controller dynamic gain or frequency-dependent chemosensitivity. As compared with 16 nonapneic, nonobese control subjects, a group of nine obese OSA patients had a higher peak response and a more rapid and irregular recovery phase of the closed-loop CO2 response in the PRBS test. The two groups had similar open-loop responses in the PRBS test, suggesting that central dynamic CO2 chemosensitivity was not abnormal in OSA. We conclude that the differences between OSA patients and controls in the closed-loop response in the PRBS test are not due to differences in dynamic controller gain, but are related to differences in dynamic plant gain and/or negative ventilatory feedback. In addition to OSA, obesity may affect these variables and may have been responsible for our findings.

Overview

Integrity signals

Registry

Crossref · 10.1164/ajrccm.158.4.9712105

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. Phillipson, 1978, Control of breathing during sleep., Am. Rev. Respir. Dis., 118, 909

Cited by

See all 131

Metadata

Authors
HUDGEL, D. W., GORDON, E. A., THANAKITCHARU, S., & BRUCE, E. N.
Affiliations
University of Kentucky (US)
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1998-10-01
Volume
158
Issue
4
Pages
1142-1149
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2019421626
Cited by
131
References
28
Citations by year
2026: 3 · 2025: 3 · 2024: 5 · 2023: 1 · 2022: 4 · 2021: 4 · 2020: 2 · 2019: 5 · 2018: 6 · 2017: 4 · 2016: 5 · 2015: 7 · 2014: 9 · 2013: 10 · 2012: 4
FWCI
1.23
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
obstructive sleep apnea, ventilation control, ventilatory instability, closed-loop response, open-loop response, CO2 chemosensitivity, obesity, upper airway resistance
MeSH terms
Adult, Airway Resistance, Inhalation, Carbon Dioxide, Chemoreceptor Cells, Feedback, Female, Humans, Hypercapnia, Male, Maximal Voluntary Ventilation, Obesity, Pulmonary Gas Exchange, Respiration, Respiratory Muscles, Sleep Apnea Syndromes, Tidal Volume, Time Factors, Respiratory Mechanics, Hyperoxia, Area Under Curve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Instability of Ventilatory Control in Patients with Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/ajrccm.158.4.9712105
The paper
HUDGEL, D. W., GORDON, E. A., THANAKITCHARU, S., & BRUCE, E. N. (1998). Instability of Ventilatory Control in Patients with Obstructive Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.158.4.9712105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.