CoChat

Alveolar Epithelial Fluid Transport Capacity in Reperfusion Lung Injury after Lung Transplantation

WARE, LORRAINE B., GOLDEN, JEFFREY A., FINKBEINER, WALTER E., MATTHAY, MICHAEL A. · 1999 · American Journal of Respiratory and Critical Care Medicine
Cited by 138

The DOI matches its Crossref record.

Abstract

Reperfusion lung injury is an important cause of morbidity and mortality after orthotopic lung transplantation. The purpose of this study was to investigate the function of the alveolar epithelium in the setting of reperfusion lung injury. Simultaneous samples of pulmonary edema fluid and plasma were collected from eight patients with severe post-transplantation reperfusion edema. The edema fluid to plasma protein ratio was measured, an indicator of alveolar-capillary barrier permeability. The initial edema fluid to plasma protein ratio was > 0.75 in six of eight patients, confirming the presence of increased permeability of the alveolar-capillary barrier. Graft ischemic time was positively correlated with the degree of permeability (r = 0.77, p < 0.05). In four of six patients with serial samples, there was a high rate of alveolar fluid clearance (19 +/- 9%/h, mean +/- SD). Alveolar fluid clearance was calculated from serial samples in six patients. Intact alveolar fluid clearance correlated with less histologic injury, rapid resolution of hypoxemia, and more rapid resolution of radiographic infiltrates. The two patients with no net alveolar fluid clearance had persistent hypoxemia and more severe histologic injury. This study provides the first direct evidence that increased permeability to protein is the usual cause of reperfusion edema after lung transplantation, with longer ischemic times associated with greater permeability to protein in the transplanted lung. The high rates of alveolar fluid clearance indicate that the fluid transport capacity of the alveolar epithelium may be well preserved in the allograft despite reperfusion lung injury. The ability to reabsorb fluid from the alveolar space was a marker of less severe reperfusion injury, whereas the degree of alveolar-capillary barrier permeability to protein was not. Measurement of alveolar fluid clearance may be useful to assess the severity of reperfusion lung injury and to predict outcome when pulmonary edema develops after lung transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.159.3.9802105

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 138

Metadata

Authors
WARE, L. B., GOLDEN, J. A., FINKBEINER, W. E., & MATTHAY, M. A.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1999-03-01
Volume
159
Issue
3
Pages
980-988
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W1974324988
Cited by
138
References
0
FWCI
9.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Alveolar Epithelial Fluid Transport Capacity in Reperfusion Lung Injury after Lung Transplantation. https://app.cochat.ai/papers/10.1164/ajrccm.159.3.9802105
The paper
WARE, L. B., GOLDEN, J. A., FINKBEINER, W. E., & MATTHAY, M. A. (1999). Alveolar Epithelial Fluid Transport Capacity in Reperfusion Lung Injury after Lung Transplantation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.159.3.9802105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.