CoChat

Comparison of Esophageal Pressure with Pulse Transit Time as a Measure of Respiratory Effort for Scoring Obstructive Nonapneic Respiratory Events

ARGOD, JÉRÔME, PÉPIN, JEAN-LOUIS, SMITH, ROBIN P., LÉVY, PATRICK · 2000 · American Journal of Respiratory and Critical Care Medicine
Cited by 105

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Obstructive nonapneic respiratory events (ONAREs) are much more difficult to detect and classify than apneas unless sensitive measures of respiratory effort and airflow are employed. The aim of this study was to compare two measures of respiratory effort, esophageal pressure monitoring (Pes) and pulse transit time (PTT), for scoring of ONAREs by visual analysis. Nine men (age 49 +/- 10 yr) with mild to moderate sleep apnea syndrome (AHI of 25.1 +/- 10. 8/h) were studied and 340 ONAREs (hypopneas and upper airway resistance episodes) were randomly selected for scoring by two experienced observers. Each observer blindly scored each ONARE twice (once with Pes and once with PTT) with a concurrent pneumotachography trace available for airflow quantification. This permitted the respiratory events scored with PTT to be compared with those scored with Pes, and in addition interobserver variability could be assessed for each signal. Even though standard criteria were used for scoring, there was significant interobserver variability for both Pes (29.7%) and PTT (37.1%). Taking those events for which there was agreement between the observers, PTT had a sensitivity of 79.9% and a positive predictive value of 91.2% (using Pes as the gold standard). In those ONAREs for which there was agreement between the two observers there was a larger percentage reduction in airflow compared to ONAREs that did not concur (51 versus 30.3%, p < 0.001), a larger increase in respiratory effort as assessed by PTT (slope of PTT: 23.1 versus 14. 3 arbitrary units, p < 0.01), and a higher incidence in autonomic microarousals detected with PTT (90 versus 45% of ONAREs, p < 0.006). Subtle respiratory events are more difficult to detect than apneas or frank hypopneas. When comparing PTT with esophageal pressure in detecting those events the sensitivity of PTT is good but limited when the reduction in airflow, the increase in respiratory effort, or the arousal reaction is the less clear. However, PTT appears to be a good noninvasive alternative to Pes in the detection of nonapneic obstructive respiratory events, and its ability to detect autonomic arousal gives this physiological signal added clinical usefulness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.162.1.9907086

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 105

Metadata

Authors
ARGOD, J., PÉPIN, J.-L., SMITH, R. P., & LÉVY, P.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2000-07-01
Volume
162
Issue
1
Pages
87-93
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2134966013
Cited by
105
References
4
FWCI
3.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Esophageal Pressure with Pulse Transit Time as a Measure of Respiratory Effort for Scoring Obstructive Nonapneic Respiratory Events. https://app.cochat.ai/papers/10.1164/ajrccm.162.1.9907086
The paper
ARGOD, J., PÉPIN, J.-L., SMITH, R. P., & LÉVY, P. (2000). Comparison of Esophageal Pressure with Pulse Transit Time as a Measure of Respiratory Effort for Scoring Obstructive Nonapneic Respiratory Events. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.162.1.9907086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.