Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record.

Continuous Positive Airway Pressure during Fiberoptic Bronchoscopy in Hypoxemic Patients: A Randomized Double-Blind Study Using A New Device

MAITRE, BERNARD, JABER, SAMIR, MAGGIORE, SALVATORE M., BERGOT, EMMANUEL, RICHARD, JEAN CHRISTOPHE, BAKTHIARI, HAMID, HOUSSET, BRUNO, BOUSSIGNAC, GEORGES, BROCHARD, LAURENT · 2000 · American Journal of Respiratory and Critical Care Medicine

Abstract

Fiberoptic bronchoscopy (FOB) may worsen oxygenation and clinical status in severely hypoxemic patients. We conducted a prospective, randomized double-blind trial to compare the delivery of continuous positive airway pressure (CPAP) as a tool for maintaining oxygenation during FOB, to the delivery of oxygen only. Thirty consecutive patients who needed FOB for diagnostic purposes were enrolled. Their arterial oxygen pressure (Pa(O(2))) to inspired oxygen fraction (FI(O(2))) ratio was below 300 mm Hg. CPAP was generated by a simple new device open to the atmosphere. During FOB and the 30 min thereafter, pulse oximetry values (Sp(O(2))) were significantly higher in the CPAP than the Oxygen group (95.7 +/- 1.9% versus 92.6 +/- 3.1, p = 0.02). The lowest Sp(O(2)) values were observed in the Oxygen group (93.5 +/- 2.4% versus 88.6 +/- 3.4, p = 0.002). Arterial blood gases 15 min after FOB showed that Pa(O(2)) had increased in the CPAP group and decreased in the Oxygen group (DeltaPa(O(2)) = +10.5% +/- 16.9 versus -15% +/- 16.6, p = 0.01). Five patients in the Oxygen group, but none in the CPAP group, developed respiratory failure in the 6 h after FOB and required ventilatory assistance (p = 0.03). We conclude that in hypoxemic patients, the use of a new CPAP device during FOB allowed minimal alterations in gas exchange and prevented subsequent respiratory failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.162.3.9910117

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
MAITRE, B., JABER, S., MAGGIORE, S. M., BERGOT, E., RICHARD, J. C., BAKTHIARI, H., HOUSSET, B., BOUSSIGNAC, G., & BROCHARD, L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2000-09-01
Volume
162
Issue
3
Pages
1063-1067
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2108051257
Cited by
195
References
0
FWCI
5.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous Positive Airway Pressure during Fiberoptic Bronchoscopy in Hypoxemic Patients: A Randomized Double-Blind Study Using A New Device. https://app.cochat.ai/papers/10.1164/ajrccm.162.3.9910117
The paper
MAITRE, B., JABER, S., MAGGIORE, S. M., BERGOT, E., RICHARD, J. C., BAKTHIARI, H., HOUSSET, B., BOUSSIGNAC, G., & BROCHARD, L. (2000). Continuous Positive Airway Pressure during Fiberoptic Bronchoscopy in Hypoxemic Patients: A Randomized Double-Blind Study Using A New Device. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.162.3.9910117

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.