Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 484

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Noninvasive Versus Conventional Mechanical Ventilation: An Epidemiologic Survey

CARLUCCI, ANNALISA, RICHARD, JEAN-CHRISTOPHE, WYSOCKI, MARC, LEPAGE, ERIC, BROCHARD, LAURENT, the SRLF Collaborative Group on Mechanical Ventilation·2001·American Journal of Respiratory and Critical Care Medicine

Abstract

A prospective survey was performed over a period of 3 wk among 42 intensive care units to assess the incidence of use and effectiveness of noninvasive mechanical ventilation (NIV) in clinical practice. All patients requiring ventilatory support for acute respiratory failure (ARF), either with endotracheal intubation (ETI) or NIV, were included. Ventilatory support was required in 689 patients, 581 with ETI and 108 (16%) with NIV (35% of patients not intubated on admission). Reasons for mechanical ventilation were coma (30%), cardiogenic pulmonary edema (7%), and hypoxemic (48%) and hypercapnic ARF (15%). NIV was never used for patients in coma (who were excluded from further analysis), but was used in 14% of patients with hypoxemic ARF, in 27% of those with pulmonary edema, and in 50% of those with hypercapnic ARF. NIV was followed by ETI in 40% of cases. The incidence of both nosocomial pneumonia (10% versus 19%, p = 0.03), and mortality (22% versus 41%, p < 0.001) was lower in NIV patients than in those with ETI. After adjusting for differences at baseline, Simplified Acute Physiology Score (SAPS) II (odds ratio [OR] = 1.05 per point; confidence interval [CI]: 1.04 to 1.06), McCabe/Jackson score (OR = 2.18; CI: 1.57 to 3.03), and hypoxemic ARF (OR = 2.30; CI: 1.33 to 4.01) were identified as risk factors explaining mortality; success of NIV was associated with a lower risk of pneumonia (OR = 0.06; CI: 0.01 to 0.45) and of death (OR = 0.16; CI: 0.05 to 0.54). In NIV patients, SAPS II and a poor clinical tolerance predicted secondary ETI. Failure of NIV was associated with a longer length of stay. In conclusion, NIV can be successful in selected patients, and is associated with a lower risk of pneumonia and death than is ETI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.163.4.2006027

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 484

Metadata

Authors
CARLUCCI, A., RICHARD, J.-C., WYSOCKI, M., LEPAGE, E., BROCHARD, L., & the SRLF Collaborative Group on Mechanical Ventilation
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2001-03-15
Volume
163
Issue
4
Pages
874-880
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2165073838
Cited by
484
References
1
FWCI
20.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Versus Conventional Mechanical Ventilation: An Epidemiologic Survey. https://app.cochat.ai/papers/10.1164/ajrccm.163.4.2006027
The paper
CARLUCCI, A., RICHARD, J.-C., WYSOCKI, M., LEPAGE, E., BROCHARD, L., & the SRLF Collaborative Group on Mechanical Ventilation. (2001). Noninvasive Versus Conventional Mechanical Ventilation: An Epidemiologic Survey. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.163.4.2006027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.