CoChat

Characterization of Obstructive Nonapneic Respiratory Events in Moderate Sleep Apnea Syndrome

CRACOWSKI, CLAIRE, PÉPIN, JEAN-LOUIS, WUYAM, BERNARD, LÉVY, PATRICK · 2001 · American Journal of Respiratory and Critical Care Medicine
Cited by 57

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Obstructive nonapneic respiratory events (ONAREs, i.e., obstructive hypopneas [OHs] and respiratory effort related arousals [RERAs]) are clinically important as producing sleep fragmentation but are much more difficult to detect and classify than obstructive apneas. We characterized 1,061 ONAREs in 15 unselected patients with moderate sleep apnea-hypopnea syndrome (OSAHS) according to the 1999 American Academy of Sleep Medicine (AASM) Task Force recommendations concerning accurate skills for respiratory measurements (i.e., pneumotachograph and esophageal pressure [Pes]) and definitions of respiratory events. OHs were defined as > or = 50% decrease in flow or < 50% but > or = 30% decrease in flow associated with either a desaturation of > or = 3% or a cortical arousal. RERAs corresponded to a less than 30% decrease in flow associated with an arousal. OHs represented a large majority of the events (79.9%, n = 848). Among the events demonstrating a 30 to 50% reduction in flow (n = 392), the occurrence of a cortical arousal permitted the classification of 246 events as OHs (62.8%). RERAs represented only 5.3% of the events. Finally 14.8% of the events were classified as indeterminate owing to a < 50% and > or = 30% airflow decrease without arousal or desaturation or an airflow decrease less than 30% without arousal. The same level of DeltaPes was observed at the end of OHs and RERAs (21.9 +/- 5.5 versus 18.9 +/- 5.7 cm H(2)O respectively [NS]) whereas the reduction in flow was as expected, higher for OH (57.9 +/- 10.7 versus 21.3 +/- 4.9%). In a population of moderate OSAHS, OH represented the dominant type of ONAREs when RERAs should be considered as specific but relatively rare respiratory events. The occurrence and the recognition of a microarousal represented the key associated factor for classifying respiratory events as hypopneas. The high rate (15%) of unclassified events demonstrated some limitations in the AASM Task Force recommendations for definitions of respiratory events. Similar levels of DeltaPes found at the end of RERAs and OHs, although the reduction in flow was higher for OHs, suggest that different levels of collapsibility can exist throughout the night in a given patient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.164.6.2002116

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
CRACOWSKI, C., PÉPIN, J.-L., WUYAM, B., & LÉVY, P.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2001-09-15
Volume
164
Issue
6
Pages
944-948
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2001786970
Cited by
57
References
2
FWCI
2.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.