One-Night Mandibular Advancement Titration for Obstructive Sleep Apnea Syndrome: A Pilot Study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The effect of a dental appliance (DA) is usually evaluated in a single mandibular position reached after several weeks and corresponding to either improvement of symptoms or intolerance to any further advancement. The purpose of this study was to test the feasibility of one-night evaluation of the efficacy of a DA. The study population consisted of seven patients (six men) with obstructive sleep apnea syndrome (66.9 +/- 32.4 apneas and/or hypopneas per hour). Patients underwent two consecutive polysomnographies; first with a temporary DA (two arches connected by a hydraulic system) progressively adjusted during the night to correct sleep disordered breathing and second with a permanent DA (two arches connected by Herbst attachments) set to the effective degree of advancement during the titration night. All patients completed the protocol. The mean mandibular advancement reached during the titration night was 12.6 +/- 2.7 mm. Arousal was never observed during or for 60 seconds following advancement. The apnea-hypopnea index (AHI) was significantly reduced from 66.9 +/- 32.4 to 26.1 +/- 20.7 per hour during the titration night from the diagnostic night (p < 0.01). During the second night, the AHI was 19.6 +/- 20.2 per hour and was less than 20 per hour in 71.4% of patients and less than 10 per hour in 42.9% of patients. The efficacy of a DA can be evaluated during a single night of polysomnography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized, Controlled Study of a Mandibular Advancement Splint for Obstructive Sleep Apnea
MEHTA, A., QIAN, J., PETOCZ, P., DARENDELILER, M. A., & CISTULLI, P. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2004213 · Cited by 514
Ferguson, K. A., Ono, T., Lowe, A. A., al-Majed, S., Love, L. L., & Fleetham, J. A. (1997) · Thorax · doi:10.1136/thx.52.4.362 · Cited by 391
Cited by
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687
Efficacy of Positive Airway Pressure and Oral Appliance in Mild to Moderate Obstructive Sleep Apnea
Barnes, M., McEvoy, R. D., Banks, S., Tarquinio, N., Murray, C. G., Vowles, N., & Pierce, R. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200311-1571oc · Cited by 597
“Although two groups (20, 21) have shown that the potential improvement in sleep-disordered breathing with oral appliance use could be titrated and predicted from an overnight sleep study, no other outcomes were measured.”
BackgroundOral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
“98,99 This method involves use of a remotely controlled intraoral device during an attended sleep study to incrementally advance the mandible until sleep disordered breathing events are eliminated, analogous to a CPAP pressure titration study.”
Self-citationMandibular Advancement Devices in 630 Men and Women With Obstructive Sleep Apnea and Snoring
Marklund, M., Stenlund, H., & Franklin, K. A. (2004) · Chest · doi:10.1378/chest.125.4.1270 · Cited by 372
Review of oral appliances for treatment of sleep-disordered breathing
Hoffstein, V. (2007) · Sleep and Breathing · doi:10.1007/s11325-006-0084-8 · Cited by 355
Metadata
- Authors
- Pételle, B., Vincent, G., Gagnadoux, F., Rakotonanahary, D., Meyer, B., & Fleury, B.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-04-15
- Volume
- 165
- Issue
- 8
- Pages
- 1150-1153
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2097302874
- Cited by
- 101
- References
- 2
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.