Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 61

The DOI matches its Crossref record.

Plasma Hypoxanthine and Exercise

Ketai, Loren H., Simon, Richard H., Kreit, John W., Grum, Cyril M.·1987·American Review of Respiratory Disease

Abstract

During exercise, ATP is converted to ADP and AMP to supply energy for muscular contraction. It is then regenerated via various pathways of intermediary metabolism. However, with high levels of exercise, net ATP degradation in muscle occurs. In exercise and other clinical situations, adenine nucleotide degradation leads to an accumulation of degradative purine products including hypoxanthine. In an effort to monitor events of energy metabolism, we examined plasma hypoxanthine levels at various exercise intensities. Peak plasma hypoxanthine levels after maximal exercise (18.9 ± 2.6 µM, mean ± SEM) were significantly greater than resting levels (1.1 ± 0.1 µM; p < 0.001). Hypoxanthine levels after steady state exercise at 52,76, and 97% of ventilatory threshold did not exceed resting levels. However, plasma hypoxanthine rose significantly after exercise at 124% of ventilatory threshold (6.3 ± 1.0 µM; p < 0.01) and at 152% of ventilatory threshold (17.0 ± 3.6 µM; p < 0.001). Exercise at subventilatory threshold intensity (74% of ventilatory threshold) for a prolonged time period, such that total work equaled that performed at 152% of ventilatory threshold, did not elevate hypoxanthine levels (0.46 ± 0.1 µM) above resting values. We conclude that elevation of plasma hypoxanthine levels occur during exercise at intensities that exceed the ventilatory threshold and indicate that net adenine nucleotide degradation has occurred.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/136.1.98

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 12

  1. 10.1172/JCI107693 · DOI
  2. 10.1016/0009-8981(81)90108-X · DOI
  3. 1979, Cardiol, 9, 227
  4. 10.1016/0002-9149(77)90100-X · DOI
  5. 10.1016/0024-3205(80)90219-2 · DOI
  6. 10.1159/000128021 · DOI
  7. 10.1378/chest.88.5.763 · DOI
  8. 10.1016/0026-0495(80)90067-0 · DOI
  9. 10.1146/annurev.bi.47.070178.003255 · DOI · Paper page
  10. 1981, London: Pitman Medical, 1
  11. 1985, Sci Sports Exerc, 17, 22
  12. 1975, Scand J Clin Lab Invest, 35, 211

Cited by

See all 61

Metadata

Authors
Ketai, L. H., Simon, R. H., Kreit, J. W., & Grum, C. M.
Venue
American Review of Respiratory Disease
Published
1987-07-01
Volume
136
Issue
1
Pages
98-101
ISSN
0003-0805
Cited by
61
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plasma Hypoxanthine and Exercise. https://app.cochat.ai/papers/10.1164/ajrccm/136.1.98
The paper
Ketai, L. H., Simon, R. H., Kreit, J. W., & Grum, C. M. (1987). Plasma Hypoxanthine and Exercise. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/136.1.98

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.