The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Prospective Study of Lung Water Measurements during Patient Management in an Intensive Care Unit
Abstract
We prospectively evaluated a protocol that included extravascular thermal volume (ETV) as a measure of extravascular lung water (EVLW) instead of pulmonary artery wedge pressure (Ppaw) measurements to guide the hemodynamic management of 48 critically ill patients. Patients were randomized to either a protocol management (PM), or to a routine management (RM) group. In the RM group, EVLW measurements were unknown to the primary care physicians. The 2 groups were similar with respect to age, gender, and severity of illness. In patients with initially high EVLW, EVLW fell to a greater extent in PM than in RM patients (18 +/- 5 versus 4 +/- 8% decrease, p less than 0.05). This difference was even greater in patients with heart failure. No adverse effects on oxygenation or renal function occurred in following the protocol. Mortality for the groups as a whole was similar, but was significantly better (p less than 0.05) for PM patients with initially high EVLW and normal Ppaw (predominantly patients with sepsis or the adult respiratory distress syndrome). For both groups, patients with an initial EVLW greater than 14 ml/kg had a significantly greater mortality than did those with a lesser amount of EVLW: 13 of 15 (87%) versus 13 of 32 (41%), p less than 0.05. We conclude that management based on a protocol using EVLW measurements is safe, may hasten the resolution of pulmonary edema, and may lead to improved outcome in some critically ill patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Connors, A. F., McCaffree, D. R., & Gray, B. A. (1983) · New England Journal of Medicine · doi:10.1056/nejm198302033080508 · Cited by 365
Cited by
Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
Sakka, S. G., Rühl, C. C., Pfeiffer, U. J., Beale, R., McLuckie, A., Reinhart, K., & Meier-Hellmann, A. (2000) · Intensive Care Medicine · doi:10.1007/s001340050043 · Cited by 920
Acute lung injury and the acute respiratory distress syndrome: a clinical review
Wheeler, A. P., & Bernard, G. R. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60604-7 · Cited by 904
“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Mitchell, J. P., Schuller, D., Calandrino, F. S., & Schuster, D. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.5.990 · Cited by 587
Self-citationThe Acute Respiratory Distress Syndrome
Kollef, M. H., & Schuster, D. P. (1995) · New England Journal of Medicine · doi:10.1056/nejm199501053320106 · Cited by 550
Self-citation
Metadata
- Authors
- Eisenberg, P. R., Hansbrough, J. R., Anderson, D., & Schuster, D. P.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1987-08
- Volume
- 136
- Issue
- 3
- Pages
- 662-668
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2002603559
- Cited by
- 197
- References
- 1
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.