Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record.

Use and Misuse of Metered-dose Inhalers by Patients with Chronic Lung Disease: A Controlled, Randomized Trial of Two Instruction Methods

De Blaquiere, Patricia, Christensen, Dale B., Carter, William B., Martin, Thomas R.·1989·American Review of Respiratory Disease

Abstract

Abstract Metered-dose inhalers are often used incorrectly by patients with chronic airflow obstruction, and there is a lack of controlled studies designed to evaluate methods to teach the correct use of these devices. Therefore, we screened 100 consecutive stable outpatients for correct or incorrect inhaler use and then conducted a randomized trial of two methods to teach correct use. Patients were classified as correct or incorrect users with a modified metered-dose inhaler containing a thermistor that detected inspiration, inhaler activation, and the duration of breathholding. Patients were classified as incorrect users if they failed to: (1) activate the inhaler once during inspiration, and/or (2) hold their breath at the end of inspiration. There were 38 correct users and 62 incorrect users. Incorrect users were randomized to one of two teaching protocols: (1) standardized verbal instruction alone, or (2) standardized verbal instruction plus an automatic visual signal during inspiration. Incorrect users were restudied 6 to 10 wk later to reassess technique. Both treatment protocols were equally effective in converting incorrect to correct users. However, the verbal instruction alone required significantly less time than the instruction with the mechanical aid. for all subjects, the proportion using correct technique declined over time, particularly for incorrect users. We also examined a series of patient characteristics, obtained by questionnaire and spirometry, to determine whether they could be used in the clinical setting to identify incorrect users. By discriminant analysis, a group of four variables predicted correct metered-dose inhaler use: bron-chodilator responsiveness, a history of additional instruction about proper technique, verbal knowledge of the correct inhaler maneuvers, and the patient's perception of whether it is important to use an inhaler. Responsiveness to inhaled bronchodilators was the single best predictor of correct inhaler use. This study indicates that verbal instruction alone is as effective as verbal instruction supplemented with a visual aid in teaching the correct use of metered-dose inhalers. Patient characteristics can be used to identify those patients who are likely to use metered-dose inhalers incorrectly, so that teaching efforts can be concentrated on these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/140.4.910

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
De Blaquiere, P., Christensen, D. B., Carter, W. B., & Martin, T. R.
Venue
American Review of Respiratory Disease
Published
1989-10
Volume
140
Issue
4
Pages
910-916
ISSN
0003-0805 (ISSN-L)
OpenAlex
W1982088334
Cited by
185
References
0
FWCI
6.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use and Misuse of Metered-dose Inhalers by Patients with Chronic Lung Disease: A Controlled, Randomized Trial of Two Instruction Methods. https://app.cochat.ai/papers/10.1164/ajrccm/140.4.910
The paper
De Blaquiere, P., Christensen, D. B., Carter, W. B., & Martin, T. R. (1989). Use and Misuse of Metered-dose Inhalers by Patients with Chronic Lung Disease: A Controlled, Randomized Trial of Two Instruction Methods. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/140.4.910

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.