Intraindividual Variability in Serial Measurements of D l CO and Alveolar Volume over One Year in Eight Healthy Subjects Using Three Independent Measuring Systems
The DOI matches its Crossref record.
Abstract
To evaluate intraindividual and between-machine variability in DLCO, one technician performed triplicate measurement of DLCO in eight healthy subjects on three consecutive days using three different systems (Collins [C], Gould [G], SRL [S]) on five separate occasions over the course of 1 yr. For each subject and machine, we calculated the coefficient of variation (CV) of the DLCO and its associated alveolar volume (VA) and inspiratory vital capacity (IVC) over the five different measurement periods using the mean value for each period. CV (in %) for DLCO in each of the eight subjects for each machine varied from 2.4 to 7.1% for machine C, 4.1 to 10.5% for machine G, and 2.5 to 8.7% for machine S. Two-way ANOVA showed significant differences in CV for DLCO and IVC but not for VA across subjects (p less than 0.01) and for DLCO, VA, and IVC across machines (p less than 0.03): CV for DLCO was higher for G than for C or S; CV for VA and IVC was lower for C than for G or S. Multiple regression did not show a significant relationship between within-individual CV for DLCO and that for VA or IVC. We conclude that variability in DLCO measurements is affected by both subject and machine, but, at least in healthy cooperative subjects, it does not appear to be affected by variability in VA or IVC. For the average subject and the two less variable machines we tested, DLCO measurements could vary within the same subject as much as +/- 9.6% (two-tailed 95% confidence interval) with repeated measurements over 1 yr.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Standardisation of the single-breath determination of carbon monoxide uptake in the lung
MacIntyre, N., Crapo, R. O., Viegi, G., Johnson, D. C., van der Grinten, C. P. M., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034905 · Cited by 2,255
2017 ERS/ATS standards for single-breath carbon monoxide uptake in the lung
Graham, B. L., Brusasco, V., Burgos, F., Cooper, B. G., Jensen, R., Kendrick, A., MacIntyre, N. R., Thompson, B. R., & Wanger, J. (2017) · European Respiratory Journal · doi:10.1183/13993003.00016-2016 · Cited by 972
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Crapo, R. O. (1994) · New England Journal of Medicine · doi:10.1056/nejm199407073310107 · Cited by 576
Metadata
- Authors
- Hathaway, E. H., Tashkin, D. P., & Simmons, M. S.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-12
- Volume
- 140
- Issue
- 6
- Pages
- 1818-1822
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1983266158
- Cited by
- 60
- References
- 0
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraindividual Variability in Serial Measurements of D l CO and Alveolar Volume over One Year in Eight Healthy Subjects Using Three Independent Measuring Systems. https://app.cochat.ai/papers/10.1164/ajrccm/140.6.1818
- The paper
- Hathaway, E. H., Tashkin, D. P., & Simmons, M. S. (1989). Intraindividual Variability in Serial Measurements of D l CO and Alveolar Volume over One Year in Eight Healthy Subjects Using Three Independent Measuring Systems. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/140.6.1818
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.