Pressure-Time Product during Continuous Positive Airway Pressure, Pressure Support Ventilation, and T-Piece during Weaning from Mechanical Ventilation
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The objective of this study was to compare the effects of continuous positive airway pressure (CPAP), pressure support ventilation (PS), and T-piece on the pressure-time product (PTP) during weaning from mechanical ventilation. The PTP is an estimate of the metabolic work or oxygen consumption of the respiratory muscles. We studied 10 intubated patients recovering from acute respiratory failure of various etiologies. A modified continuous flow (flow-by) CPAP of 0 and 5 cm H2O (CPAP-0 and CPAP-5, respectively), PS of 5 cm H2O (PS-5), and T-piece were applied in random order for 30 min each. In the last 5 min of the 30-min periods, we measured the esophageal pressure and transdiaphragmatic pressure-time products-PTP(es) and PTP(di), cm H2O·s/min, respectively— multiplied by respiratory frequency. Breathing pattern, total lung resistance (Rl), quasi-static lung compliance (Cl), intrinsic positive end-expiratory pressure (PEEPi), end-expiratory transpulmonary pressure (Ptpexp), arterial blood gases, blood pressure, and heart rate were also measured. In comparison to T-piece, CPAP-5 decreased PTP(es) 40% (p < 0.01) and PTP(di) 43% (p < 0.02), whereas PS-5 decreased PTP(es) 34% (p < 0.01) and PTP(di) 38% (p < 0.05). The decrease in PTP(es) with CPAP-5 was associated with a significant reduction in Rl, and to a less extent in PEEPi relative to airway pressure. The contribution of the decrease in PEEPi to the reduction in PTP(es) amounted to 36%. With PS-5, respiratory system mechanics and PEEPi were not significantly different compared with T-piece. With CPAP-0, PTP tended to be lower than with T-piece. This was likely due to the inherent small end-inspiratory positive pressure related to the CPAP system. Breathing pattern, arterial blood gas measurements, and hemodynamics were similar in all the ventilatory modes. In conclusion, during weaning from mechanical ventilation of patients recovering from acute respiratory failure, low levels of CPAP and PS significantly decrease the pressure-time product by 40 and 34%, respectively, compared with T-piece.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076
Brochard, L., Harf, A., Lorino, H., & Lemaire, F. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.2.513 · Cited by 630
Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction
Smith, T. C., & Marini, J. J. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.4.1488 · Cited by 511
Reflexes Evoked from Tracheobronchial Tree and Lungs
Coleridge, H. M., & Coleridge, J. C. G. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030212 · Cited by 348
Marini, J. J., Smith, T. C., & Lamb, V. (1986) · Journal of Critical Care · doi:10.1016/s0883-9441(86)80114-9 · Cited by 244
Steinberg, D. (1974) · The Lancet · doi:10.1016/s0140-6736(74)93307-8 · Cited by 197
Should PEEP Be Used in Airflow Obstruction?
Marini, J. J. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.1.1 · Cited by 179
Intrinsic PEEP and Arterial PCO2 in Stable Patients with Chronic Obstructive Pulmonary Disease
Haluszka, J., Chartrand, D. A., Grassino, A. E., & Milic-Emili, J. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.5_pt_1.1194 · Cited by 173
Pengelly, L. D., Alderson, A. M., & Milic-Emili, J. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.30.6.797 · Cited by 170
Martin, J. G., Shore, S. A., & Engel, L. A. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.812 · Cited by 158
Pressure-time product, flow, and oxygen cost of resistive breathing in humans
Collett, P. W., Perry, C., & Engel, L. A. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.4.1263 · Cited by 155
Rochester, D. F., & Bettini, G. (1976) · Journal of Clinical Investigation · doi:10.1172/jci108322 · Cited by 126
Intrinsic PEEP and arterial Pco 2 in stable patients with chronic obstructive pulmonary disease
Hałuszka, J. (1990) · Medical Entomology and Zoology · Cited by 121
Gandevia, S. C., & McKenzie, D. K. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1420 · Cited by 113
Kawai, H., Kaneko, J. H., & Watanabe, N. (1985) · Journal of Applied Physics · doi:10.1063/1.336119 · Cited by 113
Wherry, P., Sangoul, F., FOX, G. S., & MacLean, L. D. (1980) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03007768 · Cited by 10
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Physiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives
Mauri, T., Yoshida, T., Bellani, G., Goligher, E. C., Carteaux, G., Rittayamai, N., Mojoli, F., Chiumello, D., Piquilloud, L., Grasso, S., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4400-x · Cited by 554
Diaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation
Vivier, E., Mekontso Dessap, A., Dimassi, S., Vargas, F., Lyazidi, A., Thille, A. W., & Brochard, L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2547-7 · Cited by 406
Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV
Di mussi, R., Spadaro, S., Mirabella, L., Volta, C. A., Serio, G., Staffieri, F., Dambrosio, M., Cinnella, G., Bruno, F., & Grasso, S. (2016) · Critical Care · doi:10.1186/s13054-015-1178-0 · Cited by 404
Metadata
- Authors
- Sassoon, C. S. H., Light, R. W., Lodia, R., Sieck, G. C., & Mahutte, C. K.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-03
- Volume
- 143
- Issue
- 3
- Pages
- 469-475
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1969574610
- Cited by
- 238
- References
- 17
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.