The Effect of Positive Reinforcement on Hourly Compliance in Nasal Continuous Positive Airway Pressure Users with Obstructive Sleep Apnea
The DOI matches its Crossref record.
Abstract
Previous reports have described compliance with nasal continuous positive airway pressure (nCPAP) for the treatment of obstructive sleep apnea (OSA) only in terms of the number of patients able to use it beyond their initial trial night or those continuing after some home use. Because of a possible difference between the level of compliance (mean number of hours of use per 24 h) needed for symptomatic relief of OSA versus cardiovascular improvement, the level of hourly compliance in chronic nCPAP users may be important. The first part of this study prospectively examines compliance in a stable population of OSA patients already using nCPAP for 6 months to 2 yr. The second part is a prospective randomized, crossover study examining the effect of weekly (three times) then monthly (twice) positive reinforcement on hourly compliance of new nCPAP users for 3 months versus no reinforcement for 3 months. Positive reinforcement consisted of telephone discussions with the patients about the severity or complications of OSA, benefits of nCPAP, and suggestions about minimizing side effects. Using self-assessment scales, each patient reported the perceived level of improvement from the untreated to the treated condition and the prevalence and severity of side effects from the nCPAP therapy. The level of compliance in stable, chronic nCPAP users with OSA was 6.1 +/- 2.2 h/24 h (n = 9). For the new nCPAP users during the nonreinforced period, the mean compliance was 6.0 +/- 2.8 h/24 h; that during the reinforcement period was 6.0 +/- 2.7 h/24 h (NS). There was no significant correlation between perceived improvement in OSA symptoms or between the perceived side effects of nCPAP versus hourly compliance.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Improving CPAP use by patients with the sleep apnoea/hypopnoea syndrome (SAHS)
Engleman, H. M., & Wild, M. R. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0197 · Cited by 473
Side Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome
Pépin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., & Lévy, P. (1995) · Chest · doi:10.1378/chest.107.2.375 · Cited by 422
Wright, J., Johns, R., Watt, I., Melville, A., & Sheldon, T. (1997) · BMJ · doi:10.1136/bmj.314.7084.851 · Cited by 414
Metadata
- Authors
- Fletcher, E. C., & Luckett, R. A.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-05
- Volume
- 143
- Issue
- 5_pt_1
- Pages
- 936-941
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2033265042
- Cited by
- 131
- References
- 0
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Positive Reinforcement on Hourly Compliance in Nasal Continuous Positive Airway Pressure Users with Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/ajrccm/143.5_pt_1.936
- The paper
- Fletcher, E. C., & Luckett, R. A. (1991). The Effect of Positive Reinforcement on Hourly Compliance in Nasal Continuous Positive Airway Pressure Users with Obstructive Sleep Apnea. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/143.5_pt_1.936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.