Spirometry in the Lung Health Study: 1. Methods and Quality Control
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The Lung Health Study is a randomized clinical trial designed to determine whether a smoking intervention program and prescription of an inhaled bronchodilator can reduce the annual rate of decline of FEV1 (FEV1 slope) in cigarette smokers with mild to moderate airflow limitation. During the recruitment period, spirometry measurements were obtained during three screening visits from 5,887 cigarette smokers 35 to 60 yr of age. To improve the statistical power of the study to detect significant differences in the FEV1 slopes among study groups, the spirometry testing protocol carefully controls for multiple factors that are known to increase intraindividual variability of FEV1 and FVC results. These factors include participant preparation, maneuver acceptability and reproducibility, technician training and performance monitoring, equipment design and calibration, and result processing. The objective of this report is to describe the success of the spirometry quality control program in minimizing the short-term intraindividual FEV1 variability. The mean difference between the FEV1 values obtained at the second and third screening visits (mean 25 days apart) was +5.7 ml in women and -14.7 ml in men, with a mean intraindividual variability of 119 ml in women and 162 ml in men, with a coefficient of variation of 5.8% for both. During only 2.1% of the test sessions were participants unable to produce three acceptable FVC maneuvers with the two best FEV1 values matching within 5% or 100 ml. Institution of site visits and technician performance monitoring was associated with improved test session quality grades and maintenance of high quality grades thereafter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reference spirometric values using techniques and equipment that meet ATS recommendations.
Terrin, M. (1981) · PubMed · doi:10.1164/arrd.1981.124.6.763c · Cited by 1,374
Camilli, A. E., Burrows, B., Knudson, R. J., Lyle, S. K., & Lebowitz, M. D. (1987) · American Review of Respiratory Disease · doi:10.1164/arrd.1987.135.4.794 · Cited by 347
Cumulative and Reversible Effects of Lifetime Smoking on Simple Tests of Lung Function in Adults
Dockery, D. W., Speizer, F. E., Ferris, B. G., Ware, J. H., Louis, T. A., & Spiro, A. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.2.286 · Cited by 214
Assessment of respiratory function in patients with chronic obstructive airways disease.
Mungall, I. P., & Hainsworth, R. (1979) · Thorax · doi:10.1136/thx.34.2.254 · Cited by 128
Performance Evaluation of Contemporary Spirometers
Nelson, S. B., Gardner, R. M., Crapo, R. O., & Jensen, R. L. (1990) · CHEST Journal · doi:10.1378/chest.97.2.288 · Cited by 125
Concepts of normality applied to the measurement of lung function
Becklake, M. R. (1986) · The American Journal of Medicine · doi:10.1016/0002-9343(86)90678-9 · Cited by 121
Effect of Effort on Measurement of Forced Expiratory Volume in One Second
Krowka, M. J., Enright, P., RODARTE, J. R., & Hyatt, R. E. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.4.829 · Cited by 116
Self-citationBronchodilator Testing: Confidence Intervals Derived from Placebo Inhalations
Sourk, R. L., & NUGENT, K. M. (1983) · American Review of Respiratory Disease · doi:10.1164/arrd.1983.128.1.153 · Cited by 86
Rozas, C. J. (1982) · Archives of Internal Medicine · doi:10.1001/archinte.1982.00340200045012 · Cited by 59
Kanner, R. E., Schenker, M. B., Muñoz, A., & Speizer, F. E. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.720 · Cited by 47
Connett, J. E., & Lee, W. W. (1990) · Controlled Clinical Trials · doi:10.1016/0197-2456(90)90029-2 · Cited by 46
Self-citationGardner, R. M., Crapo, R. O., Billings, R. G., Shigeoka, J. W., & Hankinson, J. (1983) · CHEST Journal · doi:10.1016/s0012-3692(15)33481-4 · Cited by 18
Cited by
General considerations for lung function testing
Miller, M. R., Crapo, R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., Grinten, C. P. M. V. D., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034505 · Cited by 2,026
Self-citation(2000) · New England Journal of Medicine · doi:10.1056/nejm200012283432601 · Cited by 830
SCANLON, P. D., CONNETT, J. E., WALLER, L. A., ALTOSE, M. D., BAILEY, W. C., SONIA BUIST, A., & e Lung Health Study Research Group, D. P. T. F. T. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9901044 · Cited by 731
Self-citationSmoking and Lung Function of Lung Health Study Participants after 11 Years
Anthonisen, N. R., Connett, J. E., & Murray, R. P. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2112096 · Cited by 697
Self-citation
Metadata
- Authors
- Enright, P. L., Johnson, L. R., Connett, J. E., Voelker, H., & Buist, A. S.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-06
- Volume
- 143
- Issue
- 6
- Pages
- 1215-1223
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2137080296
- Cited by
- 296
- References
- 12
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.