Interaction of Chemical and Mechanical Respiratory Stimuli in the Arousal Response to Hypoxia in Sleeping Dogs
The DOI matches its Crossref record.
Abstract
The role of respiratory mechanoreceptor stimuli in the arousal response to hypoxia was studied in three trained dogs. The dogs breathed through a cuffed endotracheal tube inserted through a chronic tracheostomy, and resistive loads of 8 to 49 cm H2O/L/s were added to the expiratory circuit. Arterial O2 saturation (SaO2) was measured with an ear oximeter, and isocapnic progressive hypoxia was induced by a rebreathing technique. Arousal from sleep was determined by electroencephalographic and behavioral criteria. SaO2 at arousal from non-rapid eye movement (NREM) sleep increased progressively from 67.5 +/- 4.6% (mean +/- SEM), with no added resistance to 85.2 +/- 0.5% with the highest resistance (p less than 0.01), and from 60.6 +/- 0.6 to 81.6 +/- 0.4% during REM sleep (p less than 0.01). The added resistances also increased the steady-state (normoxic) level of alveolar PCO2 (PACO2). However, when PACO2 was increased to comparable levels by the addition of dead space rather than expiratory resistance to the breathing circuit, SaO2 at arousal from hypoxia was significantly lower than during expiratory resistive loading (p less than 0.05). We therefore conclude that mechanoreceptor stimuli arising from the ventilatory apparatus may contribute substantially to the arousal response to hypoxia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Obesity and obstructive sleep apnea
Gami, A. S., Caples, S. M., & Somers, V. K. (2003) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(03)00069-0 · Cited by 338
Cardiac Hypertrophy in Obstructive Sleep Apnea Syndrome
Noda, A., Okada, T., Yasuma, F., Nakashima, N., & Yokota, M. (1995) · Chest · doi:10.1378/chest.107.6.1538 · Cited by 155
Self-citationEffects of nasal surgery on sleep quality in obstructive sleep apnea syndrome with nasal obstruction
Nakata, S., Noda, A., Yasuma, F., Morinaga, M., Sugiura, M., Katayama, N., Sawaki, M., Teranishi, M., & Nakashima, T. (2008) · American Journal of Rhinology · doi:10.2500/ajr.2008.22.3120 · Cited by 104
Pathophysiologic and therapeutic implicationsof sleep apnea in congestive heart failure
Bradley, T. D., & Floras, J. S. (1996) · Journal of Cardiac Failure · doi:10.1016/s1071-9164(96)80045-5 · Cited by 78
Self-citation
Metadata
- Authors
- Yasuma, F., Kozar, L. F., Kimoff, R. J., Bradley, T. D., & Phillipson, E. A.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-06
- Volume
- 143
- Issue
- 6
- Pages
- 1274-1277
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2024540640
- Cited by
- 41
- References
- 0
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.