Proportional Assist Ventilation, a New Approach to Ventilatory Support: Theory
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The relation between inspiratory effort and ventilatory return (flow and volume) is usually abnormal in patients who require ventilatory support because of respiratory distress. Although all available support methods provide the patient with greater ventilation than would obtain with the same effort while unsupported, the relation between instantaneous effort and ventilatory consequences is not normalized. We describe an approach with which the ventilator simply amplifies patient instantaneous effort throughout inspiration while leaving the patient with complete control over all aspects of breathing pattern (tidal volume, inspiratory and expiratory durations, and flow patterns). This approach is implemented by monitoring the instantaneous rate (V) and volume (V) of gas flow from ventilator to patient and causing applied pressure (P) to change according to the equation of motion [P = f1(V) + f2(V)], where f1 and f2 are appropriately selected functions for the relation between pressure and volume (elastic assist) and pressure and flow (resistive assist). There are several potential advantages to this approach: (1) greater comfort; (2) reduction of peak airway pressure required to sustain ventilation and, hence, the potential for avoiding intubation; (3) less likelihood of overventilation; (4) preservation and enhancement of patient's own reflex, behavioral, and homeostatic control mechanisms since the ventilator essentially becomes an extension of the patient's own muscles; and (5) improved efficiency of negative pressure ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung biology in health and disease
Horsmanheimo, M., & Fudenberg, H. H. (1977) · Clinical Immunology and Immunopathology · doi:10.1016/0090-1229(77)90040-x · Cited by 796
The relation between force, velocity and integrated electrical activity in human muscles
Bigland, B., & Lippold, O. C. J. (1954) · The Journal of Physiology · doi:10.1113/jphysiol.1954.sp005044 · Cited by 766
Pepe, P., & Marini, J. J. (1982) · PubMed · doi:10.1164/arrd.1982.126.1.166 · Cited by 672
Factors inducing periodic breathing in humans: a general model
Khoo, M. C., Kronauer, R. E., Strohl, K. P., & Slutsky, A. S. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.3.644 · Cited by 579
Respiratory Function during Pressure Support Ventilation
MacIntyre, N. R. (1986) · Chest · doi:10.1378/chest.89.5.677 · Cited by 415
Reflexes Evoked from Tracheobronchial Tree and Lungs
Coleridge, H. M., & Coleridge, J. C. G. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030212 · Cited by 348
Mechanics of the human diaphragm during voluntary contraction: statics
Grassino, A., Goldman, M. D., Mead, J., & Sears, T. A. (1978) · Journal of Applied Physiology · doi:10.1152/jappl.1978.44.6.829 · Cited by 263
Marini, J. J., Smith, T. C., & Lamb, V. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.5.1169 · Cited by 231
Velocity of muscle shortening as a limiting factor in respiratory air flow
Agostoni, E., & Fenn, W. O. (1960) · Journal of Applied Physiology · doi:10.1152/jappl.1960.15.3.349 · Cited by 138
Experimentally induced cheyne-stokes breathing
Cherniack, N. S., von Euler, C., Homma, I., & Kao, F. F. (1979) · Respiration Physiology · doi:10.1016/0034-5687(79)90070-7 · Cited by 125
A model for the relation between respiratory neural and mechanical outputs. I. Theory
Younes, M. K., & Riddle, W. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.4.963 · Cited by 83
Self-citationEffect of pressure assist on ventilation and respiratory mechanics in heavy exercise
Gallagher, C. G., & Younes, M. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.66.4.1824 · Cited by 83
Self-citationAfferent Inputs to Breathing: Respiratory Sensation
Zechman, F. W., & Wiley, R. L. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030214 · Cited by 71
Load Responses, Dyspnea, and Respiratory Failure
Younes, M. K. (1990) · CHEST Journal · doi:10.1378/chest.97.3_supplement.59s · Cited by 60
Self-citationResponse of normal subjects to inspiratory resistive unloading
Gallagher, C. G., Sanii, R., & Younes, M. K. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.66.3.1113 · Cited by 28
Self-citation
Cited by
(2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.ats1000 · Cited by 790
Pathophysiology of Adult Obstructive Sleep Apnea
Eckert, D. J., & Malhotra, A. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200707-114mg · Cited by 719
“Techniques have been developed to measure loop gain of the respiratory system, such as the proportional assist ventilation (PAV) technique (53, 54).”
MethodNon-invasive ventilation in acute respiratory failure
(2002) · Thorax · doi:10.1136/thorax.57.3.192 · Cited by 652
Neural control of mechanical ventilation in respiratory failure
Sinderby, C., Navalesi, P., Beck, J., Skrobik, Y., Comtois, N., Friberg, S., Gottfried, S. B., & Lindström, L. (1999) · Nature Medicine · doi:10.1038/71012 · Cited by 636
Slutsky, A. S. (1993) · Chest · doi:10.1378/chest.104.6.1833 · Cited by 563
Metadata
- Authors
- Younes, M.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-01
- Volume
- 145
- Issue
- 1
- Pages
- 114-120
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2083971833
- Cited by
- 491
- References
- 15
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.