Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Proportional Assist Ventilation: Results of an Initial Clinical Trial

Younes, M., Puddy, A., Roberts, D., Light, R. B., Quesada, A., Taylor, K., Oppenheimer, L., Cramp, H.·1992·American Review of Respiratory Disease

Abstract

Abstract The response to proportional assist ventilation (PAV) was tested in four normal subjects during heavy exercise and in five ventilator-dependent patients recovering from assorted medical disorders. The apparatus consisted of a rolling-seal piston coupled to a motor that generated pressure in proportion to inspired flow and inspired volume, with the gains adjusted such that the proportionality between airway pressure (Paw) and instantaneous patient-generated pressure (Pmus) was approximately 1:1 (i.e., machine-amplified patient effort by a factor of 2). Normal subjects responded to PAV by decreasing their own effort, as judged from esophageal pressure, such that the changes in ventilation and breathing pattern were rather small ( e: 64.8 ± 3.6 during PAV versus 56.0 ± 4.3, p < 0.01; Vt: 2.39 ± 0.24 versus 2.02 ± 0.17, p < 0.05; f: 27.5 ± 1.9 versus 28.0 ± 2.2, NS). In patients, elastance ranged from 20 to 35 cm H2O cm/L, resistance ranged from 5 to 10 cm H2O/L/s, and maximal inspiratory pressure ranged from −16 to −65 cm H2O. After a period of observation during synchronized intermittent mechanical ventilation (SIMV) the patient was switched to PAV and maintained on it for 1 to 3 h. No patient had to be replaced on SIMV because of discomfort or deterioration in any of the monitored variables. During PAV peak airway pressure was less than half the value observed with the IMV breaths (16.6 ± 2.4 versus 35.4 ± 3.4 cm H2O, p < 0.001). Tidal volume during PAV was more than twice the patient's own volume during SIMV (0.63 ± 0.05 versus 0.23 ± 0.03 L, p < 0.001), and respiratory rate was less than the patient's own rate during SIMV (25.4 ± 3.2 versus 34.2 ± 3.5 breaths/min, p< 0.001). There were no differences in total minute ventilation (16.4 ± 1.2 versus 15.2 ± 8.0 L/min), PaCO2 (39.0 ± 2.9 versus 37.8 ± 4.0 mm Hg), or PaO2 (98 ± 5 versus 102 ± 3 mm Hg). There were also no significant changes in any of the monitored variables between early and late PAV. In summary, PAV is a feasible method of supporting ventilator-dependent patients that is well tolerated and can be implemented at much lower peak airway pressures. The spontaneously adopted breathing pattern during PAV does not appear to compromise gas exchange, at least over a few hours, in stable patients of the type studied here.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/145.1.121

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 257

Metadata

Authors
Younes, M., Puddy, A., Roberts, D., Light, R. B., Quesada, A., Taylor, K., Oppenheimer, L., & Cramp, H.
Venue
American Review of Respiratory Disease
Published
1992-01
Volume
145
Issue
1
Pages
121-129
ISSN
0003-0805 (ISSN-L)
OpenAlex
W2098544635
Cited by
257
References
4
FWCI
7.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Proportional Assist Ventilation: Results of an Initial Clinical Trial. https://app.cochat.ai/papers/10.1164/ajrccm/145.1.121
The paper
Younes, M., Puddy, A., Roberts, D., Light, R. B., Quesada, A., Taylor, K., Oppenheimer, L., & Cramp, H. (1992). Proportional Assist Ventilation: Results of an Initial Clinical Trial. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/145.1.121

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.