The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cardiac Output Response to Continuous Positive Airway Pressure in Congestive Heart Failure
Abstract
The effects of nasal continuous positive airway pressure (CPAP) were examined during cardiac catheterization in 22 patients with congestive heart failure (CHF). CPAP was applied at a level of 5 cm H2O pressure. Hemodynamic measurements were made at baseline and while on CPAP. We hypothesized that patients with high left ventricular (LV) diastolic pressures would experience an increase in cardiac index (CI). To test this hypothesis, patients were divided into two groups based on their baseline pulmonary capillary wedge pressure (PCWP): one group of 11 whose PCWP was greater than or equal to 12 mm Hg (high-PCWP group) and a second group of 11 whose PCWP was less than 12 mm Hg (low-PCWP group). Among the high-PCWP group (mean PCWP +/- SEM = 19.0 +/- 2.7 mm Hg), CI rose significantly while on CPAP (from 2.48 +/- 0.26 to 2.82 +/- 0.26 L/min/m2, p less than 0.01). Stroke volume index (SVI) also rose significantly (from 52.6 +/- 7.0 to 64.1 +/- 8.0 ml/m2, p less than 0.001). In contrast, among the low-PCWP group (PCWP = 8.3 +/- 0.6 mm Hg), CI decreased significantly while on CPAP (from 3.14 +/- 0.44 to 2.89 +/- 0.62 ml/m2, p less than 0.025). SVI fell but not significantly while on CPAP (from 75.5 +/- 8.4 to 74.2 +/- 8.5 ml/m2). Multiple stepwise linear regression analysis revealed that the only significant correlate of the magnitude of change in CI in response to CPAP was baseline PCWP (r = 0.50, p less than 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Vasodilator Therapy on Mortality in Chronic Congestive Heart Failure
Cohn, J. N., Archibald, D. G., Ziesche, S., Franciosa, J. A., Harston, W. E., Tristani, F. E., Dunkman, W. B., Jacobs, W., Francis, G. S., Flohr, K. H., et al. (1986) · New England Journal of Medicine · doi:10.1056/nejm198606123142404 · Cited by 2,400
Cited by
Continuous Positive Airway Pressure for Central Sleep Apnea and Heart Failure
Bradley, T. D., Logan, A. G., Kimoff, R. J., Sériès, F., Morrison, D., Ferguson, K., Belenkie, I., Pfeifer, M., Fleetham, J., Hanly, P., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051001 · Cited by 1,189
Self-citationDoherty, L. S., Kiely, J. L., Swan, V., & McNicholas, W. T. (2005) · Chest · doi:10.1378/chest.127.6.2076 · Cited by 485
Naughton, M. T., Rahman, M. A., Hara, K., Floras, J. S., & Bradley, T. D. (1995) · Circulation · doi:10.1161/01.cir.91.6.1725 · Cited by 466
Self-citationNaughton, M., Benard, D., Tam, A., Rutherford, R., & Bradley, T. D. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.2.330 · Cited by 393
Self-citationHemodynamic Effects of Simulated Obstructive Apneas in Humans With and Without Heart Failure
Bradley, T. D., Hall, M. J., Ando, S.-I., & Floras, J. S. (2001) · Chest · doi:10.1378/chest.119.6.1827 · Cited by 216
Self-citation
Metadata
- Authors
- Bradley, T. D., Holloway, R. M., McLaughlin, P. R., Ross, B. L., Walters, J., & Liu, P. P.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-02
- Volume
- 145
- Issue
- 2_pt_1
- Pages
- 377-382
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2023262538
- Cited by
- 378
- References
- 1
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac Output Response to Continuous Positive Airway Pressure in Congestive Heart Failure. https://app.cochat.ai/papers/10.1164/ajrccm/145.2_pt_1.377
- The paper
- Bradley, T. D., Holloway, R. M., McLaughlin, P. R., Ross, B. L., Walters, J., & Liu, P. P. (1992). Cardiac Output Response to Continuous Positive Airway Pressure in Congestive Heart Failure. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/145.2_pt_1.377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.