CoChat

Fast-CT Evaluation of the Effect of Lung Volume on Upper Airway Size and Function in Normal Men

Burger, Charles D., Stanson, Anthony W., Daniels, Bruce K., Sheedy, Patrick F., Shepard, John W. · 1992 · American Review of Respiratory Disease
Cited by 59

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The present study was performed to evaluate the regional changes in pharyngeal cross-sectional area (CSA) that occur with changes in lung volume in normal men. Fast-CT and genioglossal electromyogram (EMGgg) were used to study upper airway (UA) size and dilator muscle activity at TLC, lung volume at end-tidal inspiration (Vtei), FRC, and residual volume (RV) in 30 men with a mean age of 46 ± 3 yr and no significant sleep-disordered breathing, mean AHI = 4 ± 1 per hour. Compared with values at FRC, minimum CSA (Amin) increased 154 ± 31% at TLC (p = 0.0001), 19 ± 10% at Vtei (p = 0.03), and there was a trend toward a decrease of 31 ± 12% at RV (p = 0.07). Similar but smaller changes were observed in mean CSA (Amean), with an increase of 69 ± 14% at TLC (p = 0.0001), 8 ± 5% at Vtei (p = 0.01), and a decrease of 17 ± 7% at RV (p = 0.01). Both the velopharyngeal (VP) and orohypopharyngeal (OHP) segments of the UA increased in size with increasing lung volume. Both Amin and Amean of the OHP segment at TLC were larger (55 ± 19 and 38 ± 14%, respectively) than the respective measurements in the VP segment. EMGgg activity doubled from 12 ± 1 µV at FRC to 25 ± 1 µV at TLC (p = 0.006). There was no change in EMGgg with tidal ventilation or with exhalation to RV. Changes in CSA directly paralleled changes in lung volume in this group of normal awake nonobese men. Overall, there were no regional differences in UA response to changes in tidal volume or exhalation to RV. However, the OHP demonstrated proportionately greater enlargement than the VP at TLC. Despite significant changes in CSA with tidal breathing and exhalation to RV, there was no phasic change in EMGgg activity, indicating that changes in genioglossal muscle tone do not correlate with changes in CSA at low lung volumes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/146.2.335

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 59

Metadata

Authors
Burger, C. D., Stanson, A. W., Daniels, B. K., Sheedy, P. F., & Shepard, J. W.
Venue
American Review of Respiratory Disease
Published
1992-08
Volume
146
Issue
2
Pages
335-339
ISSN
0003-0805 (ISSN-L)
OpenAlex
W2086067118
Cited by
59
References
3
FWCI
0.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.