The Effects of Transcutaneous Electrical Stimulation during Wakefulness and Sleep in Patients with Obstructive Sleep Apnea
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Upper airway (UA) collapse in obstructive sleep apnea (OSA) is considered in part to result from the decrease in UA dilator muscle tone that occurs during sleep. We hypothesized that augmentation of UA muscle function by transcutaneous electrical stimulation (TES) might function to enlarge UA size during wakefulness and/or prevent UA collapse during sleep in patients with OSA. Eight male patients with OSA were studied both awake and asleep, with TES administered to the submental region in two patients and to both the submental and subhyoid regions in six patients. Fast-CT scans obtained at FRC and end-inspiration (VTei) demonstrated increased UA size with tidal breathing, p less than or equal to 0.05. The active generation of -10 cm H2O pressure at FRC substantially decreased UA size, p less than or equal to 0.001. However, no changes in UA size were detected at either FRC or VTei with TES applied at 50 and 100% of the maximal tolerated intensity. The collapsibility of the UA in response to the generation of -10 cm H2O pressure was also unchanged by TES. In contrast to the lack of effect of TES on UA size, voluntary protrusion of the tongue increased cross-sectional area (CSA) of the orohypopharyngeal (OHP) segment of the UA, p less than 0.05, and to a lesser extent the CSA of the distal velopharyngeal segment, p = 0.06. When applied during sleep, TES failed to prevent or improve either sleep-disordered breathing or sleep architecture.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miki, H., Hida, W., Chonan, T., Kikuchi, Y., & Takishima, T. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.5.1285 · Cited by 153
Cited by
Therapeutic Electrical Stimulation of the Hypoglossal Nerve in Obstructive Sleep Apnea
Schwartz, A. R., Bennett, M. L., Smith, P. L., De Backer, W., Hedner, J., Boudewyns, A., Van de Heyning, P., Ejnell, H., Hochban, W., Knaack, L., et al. (2001) · Archives of Otolaryngology–Head & Neck Surgery · doi:10.1001/archotol.127.10.1216 · Cited by 316
Prinsell, J. R. (1999) · Chest · doi:10.1378/chest.116.6.1519 · Cited by 294
Upper airway response to electrical stimulation of the genioglossus in obstructive sleep apnea
Oliven, A., O'Hearn, D. J., Boudewyns, A., Odeh, M., De Backer, W., van de Heyning, P., Smith, P. L., Eisele, D. W., Allan, L., Schneider, H., et al. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00203.2003 · Cited by 158
The Effect of Electrical Stimulation on Obstructive Sleep Apnea Syndrome
Guilleminault, C., Powell, N., Bowman, B., & Stoohs, R. (1995) · Chest · doi:10.1378/chest.107.1.67 · Cited by 112
Effect of genioglossus contraction on pharyngeal lumen and airflow in sleep apnoea patients
Oliven, A., Tov, N., Geitini, L., Steinfeld, U., Oliven, R., Schwartz, A. R., & Odeh, M. (2007) · European Respiratory Journal · doi:10.1183/09031936.00131106 · Cited by 85
Metadata
- Authors
- Edmonds, L. C., Daniels, B. K., Stanson, A. W., Sheedy, P. F., & Shepard, J. W.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-10
- Volume
- 146
- Issue
- 4
- Pages
- 1030-1036
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1992426133
- Cited by
- 92
- References
- 1
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effects of Transcutaneous Electrical Stimulation during Wakefulness and Sleep in Patients with Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/ajrccm/146.4.1030
- The paper
- Edmonds, L. C., Daniels, B. K., Stanson, A. W., Sheedy, P. F., & Shepard, J. W. (1992). The Effects of Transcutaneous Electrical Stimulation during Wakefulness and Sleep in Patients with Obstructive Sleep Apnea. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/146.4.1030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.