CoChat

Adequacy of Prescribing Positive Airway Pressure Therapy by Mask for Sleep Apnea on the Basis of a Partial-Night Trial

Sanders, Mark H., Kern, Nancy B., Costantino, Joseph P., Stiller, Ronald A., Studnicki, Karen, Coates, John, Orris, Suzan, Schimerman, Sharon · 1993 · American Review of Respiratory Disease
Cited by 92

The DOI matches its Crossref record.

Abstract

We tested the hypothesis that a prescription for positive-pressure therapy (including pressure level, patient-device interface, and positive-pressure modality, e.g., CPAP or BiPAP™) for obstructive sleep apnea (OSA) can be developed on the same night as the polysomnographic (PSG) diagnosis is made. Fifty consecutive patients with OSA in whom a partial-night PSG diagnosis was made (PSGD) underwent a therapeutic trial of positive-pressure therapy during the remainder of the night (PSG-PPP). The average apnea index during PSGD was 54.96 ± 36.3 (mean ± SD). On a subsequent full-night PSG (PSG-PPF), the prescription was tested. Thirty-one of the 50 patients were satisfactorily treated with CPAP, without variation of the interface during both PSG-PPP and PSG-PPF. In these patients the average pressure prescription while receiving PSG-PPF was statistically higher than during PSG-PPP (11.77 ± 3.6 versus 10.56 ± 3.6 cm H2O, respectively, p = 0.002). In 14 of these 31 patients (45%) some alteration in pressure requirement was necessary during PSG-PPF. Eleven patients required 2.5 cm H2O higher pressure and three patients required 5 cm H2O higher pressure during PSG-PPF than during PSG-PPP. There was a change of interface across the two therapeutic trials in 15 patients. Although the average pressure required by the 10 of these patients who continued to receive CPAP (i.e., did not require a change to BiPAP) was statistically the same across both trials (13 ± 3.5 versus 14 ± 2.9 cm H2O, PSG-PPP and PSG-PPF, respectively, p = 0.22), six of them required 2.5 cm H2O more pressure, and one required 5 cm H2O less pressure during the full-night trial. This distribution of pressure changes appeared similar to that observed in patients who maintained the same interface during both PSG tests. Eight patients required a change in positive-pressure modality across the two trials. Of these, seven changed from CPAP to BiPAP during PSG-PPF. We conclude that although a majority of patients with OSA can obtain a satisfactory prescription for positive-pressure therapy on the same night as the diagnosis is made, a substantial proportion of them will require alterations of that prescription, including changes in pressure, patient-device interface, or positive-pressure modality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/147.5.1169

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 92

Metadata

Authors
Sanders, M. H., Kern, N. B., Costantino, J. P., Stiller, R. A., Studnicki, K., Coates, J., Orris, S., & Schimerman, S.
Venue
American Review of Respiratory Disease
Published
1993-05
Volume
147
Issue
5
Pages
1169-1174
ISSN
0003-0805 (ISSN-L)
OpenAlex
W2080923499
Cited by
92
References
0
FWCI
2.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adequacy of Prescribing Positive Airway Pressure Therapy by Mask for Sleep Apnea on the Basis of a Partial-Night Trial. https://app.cochat.ai/papers/10.1164/ajrccm/147.5.1169
The paper
Sanders, M. H., Kern, N. B., Costantino, J. P., Stiller, R. A., Studnicki, K., Coates, J., Orris, S., & Schimerman, S. (1993). Adequacy of Prescribing Positive Airway Pressure Therapy by Mask for Sleep Apnea on the Basis of a Partial-Night Trial. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/147.5.1169

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.