The DOI matches its Crossref record.
Detection of Nonvolatile Macromolecules in Breath: A Possible Diagnostic Tool?
Abstract
The analysis of parameters in bronchoalveolar extracellular lining secretions has come into greater use in the diagnosis of diseases of the lung and respiratory passages. The bronchoalveolar lavage (BAL) method is thus used for sampling alveolar fluids or bronchial secretions. However, this method is invasive and therefore cannot be routinely employed for probe sampling. Based on the hypothesis that aerosol particles excreted in human breath reflect the composition of the bronchoalveolar extracellular lining fluid, experiments were performed to concentrate and analyze these aerosols directly using a noninvasive technique. Human exhaled air was directed through a set of cool traps and the condensate of 200 to 400 exhalations examined for nonvolatile components, such as proteins. In experiments conducted with volunteers, the amount of proteins in the breath condensate of 8 healthy individuals (of a total of 10) amounted to between 4 micrograms and 1.4 mg. The proteins were separated by two-dimensional polyacrylamide gel electrophoresis (PAGE) and compared to saliva samples of the respective volunteers. The results suggest that the proteins detected in breath originate partially from the naso-oropharyngeal tract and partially from lower regions of the airways. In clinical tests, the exhaled air of 13 patients suffering from various diseases of the respiratory tract was sampled and analyzed by immunoassays for inflammation parameters, such as interleukin-1 beta (IL-1 beta), soluble interleukin-2 receptor protein, light chain (sIL-2R), interleukin-6 (IL-6), and tumor necrosis factor alpha (TNF-alpha). In these tests, up to 370 pg IL-1 beta, 120 pg TNF-alpha, and 2,159 U sIL-2R per ml were measured in the breath condensate.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Exhaled breath condensate: methodological recommendations and unresolved questions
Horváth, I., Hunt, J., & Barnes, P. J. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00029705 · Cited by 1,284
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Dilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386
Exhaled breath condensate: An evolving tool for noninvasive evaluation of lung disease
Hunt, J. (2002) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2002.124966 · Cited by 345
Collection and Analysis of Exhaled Breath Condensate in Humans
MUTLU, G. M., GAREY, K. W., ROBBINS, R. A., DANZIGER, L. H., & RUBINSTEIN, I. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2101032 · Cited by 325
Metadata
- Authors
- Scheideler, L., Manke, H.-G., Schwulera, U., Inacker, O., & Hämmerle, H.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-09
- Volume
- 148
- Issue
- 3
- Pages
- 778-784
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2043673123
- Cited by
- 173
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Nonvolatile Macromolecules in Breath: A Possible Diagnostic Tool? https://app.cochat.ai/papers/10.1164/ajrccm/148.3.778
- The paper
- Scheideler, L., Manke, H.-G., Schwulera, U., Inacker, O., & Hämmerle, H. (1993). Detection of Nonvolatile Macromolecules in Breath: A Possible Diagnostic Tool? American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/148.3.778
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.