Ventilatory muscle function during exercise in air and oxygen in patients with chronic air-flow limitation.
The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Ventilatory muscle function was examined at rest and during exercise on a cycle ergometer in 8 patients with moderate to severe chronic air-flow limitation (FEV1, 32 +/- 4% predicted) in air and in oxygen. The diaphragmatic electromyogram (EMG) was measured using an esophageal electrode. In addition, measurements of esophageal (Pes), gastric (Pga), and transdiaphragmatic (Pdi) pressures and abdominal wall movements were made. Patients exercised to exhaustion at a constant submaximal workload (80% of maximal power output) inspiring air or 40% O2 in random order on separate days. At end-exercise in air, tidal inspiratory Pes swings were 36 +/- 4% of static maximal inspiratory Pes, and inspiratory Pdi swings were 45 +/- 7% of the static maximal Pdi. Arterial oxygen saturation decreased from 91 +/- 2% at rest to 80 +/- 5% at end-exercise in air. During exercise in air, 5 patients demonstrated a persistent and greater than 20% fall in the ratio of high frequency (150 to 350 Hz) to low frequency (20 to 46 Hz) power (H/L) of the diaphragmatic EMG, indicating impending diaphragmatic fatigue, and 2 patients had paradoxical motion of the abdominal wall. Exercise time at the same constant work load increased from 3.0 +/- 0.6 min in air to 6.4 +/- 1.2 min in O2 (p less than 0.005). At the comparable time during exercise in O2 to end-exercise in air, minute ventilation was less by 13% (p less than 0.005), which was entirely attributable to a lower frequency of breathing. Mean inspiratory and expiratory flows and heart rate were all significantly lower.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pulmonary mechanics during exercise in subjects with chronic airflow obstruction
Stubbing, D. G., Pengelly, L. D., Morse, J. L., & Jones, N. L. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.49.3.511 · Cited by 314
Cited by
Dyspnea Mechanisms, Assessment and Management: A Consensus Statement
Editorial, A. (2005) · PULMONOLOGIYA · doi:10.18093/0869-0189-2005-0-2-9-36 · Cited by 808
O’Donnell, D. E., Aaron, S., Bourbeau, J., Hernandez, P., Marciniuk, D. D., Balter, M., Ford, G., Gervais, A., Goldstein, R., Hodder, R., et al. (2007) · Canadian Respiratory Journal · doi:10.1155/2007/830570 · Cited by 693
Pathophysiology of Dyspnea in Chronic Obstructive Pulmonary Disease: A Roundtable
O'Donnell, D. E., Banzett, R. B., Carrieri-Kohlman, V., Casaburi, R., Davenport, P. W., Gandevia, S. C., Gelb, A. F., Mahler, D. A., & Webb, K. A. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200611-159cc · Cited by 380
Somfay, A., Porszasz, J., Lee, S. M., & Casaburi, R. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00082201 · Cited by 339
O'DONNELL, D. E., D'ARSIGNY, C., & WEBB, K. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.4.2007026 · Cited by 332
Metadata
- Authors
- Bye, P. T. P., Esau, S. A., Levy, R. D., Shiner, R. J., Macklem, P. T., Martin, J. G., & Pardy, R. L.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 1985-08-01
- Volume
- 132
- Issue
- 2
- Pages
- 236-40
- OpenAlex
- W1793987526
- Cited by
- 125
- References
- 1
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventilatory muscle function during exercise in air and oxygen in patients with chronic air-flow limitation. https://app.cochat.ai/papers/10.1164/arrd.1985.132.2.236
- The paper
- Bye, P. T. P., Esau, S. A., Levy, R. D., Shiner, R. J., Macklem, P. T., Martin, J. G., & Pardy, R. L. (1985). Ventilatory muscle function during exercise in air and oxygen in patients with chronic air-flow limitation. PubMed. https://doi.org/10.1164/arrd.1985.132.2.236
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.