A sleep-induced apneic threshold and its consequences.
The DOI matches its OpenAlex record.
Abstract
We have emphasized the mechanisms and consequences of sleep state effects on the manifestation of a sensitive apneic threshold. In the absence of the stabilizing influences of wakefulness, even the healthy person is vulnerable to instabilities and ventilatory control as maintenance of a rhythmic breathing pattern becomes overwhelmingly dependent on CO2. This sleep-induced unmasking of the depressant effects of hypocapnia contrasts with the relatively minor effects of sleep on the ventilatory response to a wide variety of other acute or chronic ventilatory stimuli or inhibitors. This combination of an apneic threshold with a maintained hypoxic (and asphyxic) responsiveness during non-REM sleep probably explains much of the periodic breathing in hypoxic sleep in adults and in newborns. Furthermore, applying acute hypoxia to persons with upper airways that are susceptible to collapse, i.e., snorers, showed that fluctuating chemical stimuli and the accompanying instability in ventilatory control during sleep can cause obstructive apnea, at least under conditions where chemoreceptor stimuli are sufficient to initiate some inspiratory effort but insufficient to insure a completely patent upper airway. We emphasize that chemoreceptor-induced instability and/or apnea probably plays little or no role in the induction of many other varieties of sleep apnea including most obstructive sleep apneas and perhaps even in some types of nonobstructive apnea. The consequences of these chemoreceptor-induced instabilities are, of course, substantial in terms of impairment of pulmonary gas exchange and the precipitation of events that contribute significantly to the development of chronic cor pulmonale.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
“Electrical activity from medullary inspiratory neurons, EMG activity of diaphragm and abductor muscles of the upper airway in healthy humans and/or in cats, show reductions in amplitude upon the transition from awake to NREM sleep, usually accompanied by a mild to moderate hypoventilation ( 2 to 8 mmHg PaCO2) and two-…”
BackgroundSelf-citationHanly, P. J., & Zuberi-Khokhar, N. S. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.1.8542128 · Cited by 471
Definition, discrimination, diagnosis and treatment of central breathing disturbances during sleep
Randerath, W., Verbraecken, J., Andreas, S., Arzt, M., Bloch, K. E., Brack, T., Buyse, B., De Backer, W., Eckert, D. J., Grote, L., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00959-2016 · Cited by 354
Determinants of ventilatory instability and variability
Khoo, M. C. K. (2000) · Respiration Physiology · doi:10.1016/s0034-5687(00)00157-2 · Cited by 304
Apnea–Hypopnea Threshold for CO 2 in Patients with Congestive Heart Failure
Xie, A., Skatrud, J. B., Puleo, D. S., Rahko, P. S., & Dempsey, J. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200110-022oc · Cited by 242
Self-citation
Metadata
- Authors
- Dempsey, J. A., & Skatrud, J. B.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 1986-06-01
- Volume
- 133
- Issue
- 6
- Pages
- 1163-70
- OpenAlex
- W1775009652
- Cited by
- 138
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A sleep-induced apneic threshold and its consequences. https://app.cochat.ai/papers/10.1164/arrd.1986.133.6.1163
- The paper
- Dempsey, J. A., & Skatrud, J. B. (1986). A sleep-induced apneic threshold and its consequences. PubMed. https://doi.org/10.1164/arrd.1986.133.6.1163
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.