Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 205

The DOI matches its Crossref record.

Limitations of Using Urea to Quantify Epithelial Lining Fluid Recovered by Bronchoalveolar Lavage 1– 3

Marcy, Theodore W., Merrill, William W., Rankin, John A., Reynolds, Herbert Y. · 1987 · American Review of Respiratory Disease

Abstract

The quantitation of substances in the epithelial lining fluid (ELF) of the lower respiratory tract, as obtained by bronchoalveolar lavage (BAL), is not precise because of the variable dilution of the ELF by the instilled lavage fluid. It has been reported that the absolute concentration of proteins in ELF can be determined by using the ratio of urea concentration in BAL fluid to that in serum as a method to calculate the volume of ELF recovered by BAL. Furthermore, it has been suggested that the error caused by diffusion of urea into the instilled lavage fluid can be minimized by instilling only 100 ml (5 × 20 ml) of saline rather than 300 ml (6 × 50 ml). We tested the validity of this method by collecting and individually analyzing aliquots from 2 different BAL protocols—a 100-ml (5 × 20 ml) BAL and a 300-ml (6 × 50 ml) BAL— performed in 6 healthy, nonsmoking subjects. Total protein, albumin, and urea were measured in each aliquot and in pooled fluid from each BAL procedure, and urea was measured in serum. In the 300-ml BAL, total protein and albumin concentrations tended to decrease progressively from the second to the sixth aliquots. In contrast, the urea concentration increased progressively from the first to the sixth aliquots. The concentration of albumin in ELF, calculated from the concentration of urea and albumin in each BAL aliquot, tended to decrease in each successive aliquot, becoming significant by the fourth aliquot. In the 100-ml BAL, total protein and albumin did not change significantly in successive aliquots, but the urea concentration increased from the first to the fifth aliquot. The concentration of albumin in ELF, calculated in each BAL aliquot in the 100-ml BAL, tended to decrease from the second to the fifth aliquot, but this did not reach statistical significance. These observations suggest that a significant amount of urea diffuses into the instilled BAL fluid as it dwells in the alveolar space during both the 100-ml and the 300-ml BAL protocols. This diffusion of urea will cause errors in the calculated ELF recovery despite the use of a smaller volume of lavage fluid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/arrd.1987.135.6.1276

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 205

Metadata

Authors
Marcy, T. W., Merrill, W. W., Rankin, J. A., & Reynolds, H. Y.
Venue
American Review of Respiratory Disease
Published
1987-06
Volume
135
Issue
6
Pages
1276-1280
ISSN
0003-0805 (ISSN-L)
OpenAlex
W1748543015
Cited by
205
References
0
FWCI
12.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Limitations of Using Urea to Quantify Epithelial Lining Fluid Recovered by Bronchoalveolar Lavage 1– 3. https://app.cochat.ai/papers/10.1164/arrd.1987.135.6.1276
The paper
Marcy, T. W., Merrill, W. W., Rankin, J. A., & Reynolds, H. Y. (1987). Limitations of Using Urea to Quantify Epithelial Lining Fluid Recovered by Bronchoalveolar Lavage 1– 3. American Review of Respiratory Disease. https://doi.org/10.1164/arrd.1987.135.6.1276

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.