Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.

Oral Appliance Therapy Improves Symptoms in Obstructive Sleep Apnea: A Randomized, Controlled Trial

Gotsopoulos, Helen, Chen, Carol, Qian, Jin, Cistulli, Peter A. · 2002 · American Journal of Respiratory and Critical Care Medicine

Abstract

The aim of this study was to evaluate the effect of a mandibular advancement splint (MAS) on daytime sleepiness and a range of other symptoms in obstructive sleep apnea (OSA). Using a randomized crossover design, patients received 4 weeks of treatment with MAS and a control device (inactive oral appliance), with an intervening 1-week washout. At the end of each treatment period, patients were reassessed by questionnaire, polysomnography, and multiple sleep latency test. Fifty-nine men and 14 women with a mean (± SD) age of 48 ± 11 years and proven OSA experienced a significantly improved mean (± SEM) sleep latency on the multiple sleep latency test (10.3 ± 0.5 versus 9.1 ± 0.5 minutes, p = 0.01) and Epworth sleepiness scale score (7 ± 1 versus 9 ± 1, p < 0.0001) with the MAS compared with the control device after 4 weeks. The proportion of patients with normal subjective sleepiness was significantly higher with the MAS than with the control device (82 versus 62%, p < 0.01), but this was not so for objective sleepiness (48 versus 34%, p = 0.08). Other OSA symptoms were controlled in significantly more patients with the MAS than with the control device. MAS therapy improves a range of symptoms associated with OSA.

Overview

Integrity signals

Registry

Crossref · 10.1164/rccm.200203-208oc

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 2

  1. 2000, Cochrane Database Syst Rev, 2, CD001106
  2. 1980, Sleep, 3, 425

Cited by

See all 331

Metadata

Authors
Gotsopoulos, H., Chen, C., Qian, J., & Cistulli, P. A.
Affiliations
UNSW Sydney (AU)
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2002-09-01
Volume
166
Issue
5
Pages
743-748
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2163949098
Cited by
331
References
39
Citations by year
2026: 3 · 2025: 4 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 7 · 2020: 12 · 2019: 14 · 2018: 9 · 2017: 18 · 2016: 15 · 2015: 17 · 2014: 23 · 2013: 21 · 2012: 18
FWCI
7.39
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
Keywords
obstructive sleep apnea, mandibular advancement device, oral appliance therapy, daytime sleepiness, multiple sleep latency test, Epworth Sleepiness Scale, subjective sleepiness
MeSH terms
Adult, Analysis of Variance, Equipment Design, Female, Follow-Up Studies, Humans, Male, Middle Aged, Orthodontic Appliances, Removable, Reference Values, Confidence Intervals, Treatment Outcome, Patient Satisfaction, Polysomnography, Cross-Over Studies, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oral Appliance Therapy Improves Symptoms in Obstructive Sleep Apnea: A Randomized, Controlled Trial. https://app.cochat.ai/papers/10.1164/rccm.200203-208oc
The paper
Gotsopoulos, H., Chen, C., Qian, J., & Cistulli, P. A. (2002). Oral Appliance Therapy Improves Symptoms in Obstructive Sleep Apnea: A Randomized, Controlled Trial. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200203-208oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.