Effect of Vertical Dimension on Efficacy of Oral Appliance Therapy in Obstructive Sleep Apnea

Pitsis, Andrew J., Darendeliler, M. Ali, Gotsopoulos, Helen, Petocz, Peter, Cistulli, Peter A. · 2002 · American Journal of Respiratory and Critical Care Medicine

Abstract

The aim of this study was to assess the effect of bite opening induced by a mandibular advancement splint (MAS) on efficacy and side effects in the treatment of obstructive sleep apnea. In a randomized crossover fashion, 23 adult patients received either MAS-1 (4 mm of interincisal opening) or MAS-2 (14 mm of interincisal opening) for 2 weeks, followed by the alternate treatment for 2 weeks, with an intervening 1-week washout. Complete response was defined as a resolution of symptoms and a reduction in apnea/hypopnea index (AHI) to less than 5 per hour. Partial response was defined as improved symptoms and a reduction in AHI of 50% or more, with the AHI remaining at a value of 5 or more per hour. Both MAS-1 and MAS-2 produced similar reductions in mean (+/- SEM) AHI from baseline: 21 +/- 2 versus 8 +/- 1/hour and 21 +/- 2 versus 10 +/- 2/hour, respectively (p < 0.001). Either complete response or partial response occurred in 74 and 61% of patients with MAS-1 and MAS-2, respectively. Subjective improvements were reported with both appliances by the majority of patients. Patients preferred MAS-1 (78 versus 22%, p = 0.007). This study suggests that the amount of bite opening induced by MAS does not have a significant impact on treatment efficacy but does have an impact on patient acceptance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200204-342oc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Pitsis, A. J., Darendeliler, M. A., Gotsopoulos, H., Petocz, P., & Cistulli, P. A.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2002-09-15
Volume
166
Issue
6
Pages
860-864
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2007131840
Cited by
200
References
1
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Vertical Dimension on Efficacy of Oral Appliance Therapy in Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.200204-342oc
The paper
Pitsis, A. J., Darendeliler, M. A., Gotsopoulos, H., Petocz, P., & Cistulli, P. A. (2002). Effect of Vertical Dimension on Efficacy of Oral Appliance Therapy in Obstructive Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200204-342oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.