The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of Vertical Dimension on Efficacy of Oral Appliance Therapy in Obstructive Sleep Apnea
Abstract
The aim of this study was to assess the effect of bite opening induced by a mandibular advancement splint (MAS) on efficacy and side effects in the treatment of obstructive sleep apnea. In a randomized crossover fashion, 23 adult patients received either MAS-1 (4 mm of interincisal opening) or MAS-2 (14 mm of interincisal opening) for 2 weeks, followed by the alternate treatment for 2 weeks, with an intervening 1-week washout. Complete response was defined as a resolution of symptoms and a reduction in apnea/hypopnea index (AHI) to less than 5 per hour. Partial response was defined as improved symptoms and a reduction in AHI of 50% or more, with the AHI remaining at a value of 5 or more per hour. Both MAS-1 and MAS-2 produced similar reductions in mean (+/- SEM) AHI from baseline: 21 +/- 2 versus 8 +/- 1/hour and 21 +/- 2 versus 10 +/- 2/hour, respectively (p < 0.001). Either complete response or partial response occurred in 74 and 61% of patients with MAS-1 and MAS-2, respectively. Subjective improvements were reported with both appliances by the majority of patients. Patients preferred MAS-1 (78 versus 22%, p = 0.007). This study suggests that the amount of bite opening induced by MAS does not have a significant impact on treatment efficacy but does have an impact on patient acceptance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Cited by
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687
Efficacy of Positive Airway Pressure and Oral Appliance in Mild to Moderate Obstructive Sleep Apnea
Barnes, M., McEvoy, R. D., Banks, S., Tarquinio, N., Murray, C. G., Vowles, N., & Pierce, R. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200311-1571oc · Cited by 597
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
Self-citationOral appliances for obstructive sleep apnoea
Lim, J., Lasserson, T. J., Fleetham, J., & Wright, J. J. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004435.pub3 · Cited by 418
Non-CPAP therapies in obstructive sleep apnoea
Randerath, W. J., Verbraecken, J., Andreas, S., Bettega, G., Boudewyns, A., Hamans, E., Jalbert, F., Paoli, J. R., Sanner, B., Smith, I., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00099710 · Cited by 388
Metadata
- Authors
- Pitsis, A. J., Darendeliler, M. A., Gotsopoulos, H., Petocz, P., & Cistulli, P. A.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-09-15
- Volume
- 166
- Issue
- 6
- Pages
- 860-864
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2007131840
- Cited by
- 200
- References
- 1
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Vertical Dimension on Efficacy of Oral Appliance Therapy in Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.200204-342oc
- The paper
- Pitsis, A. J., Darendeliler, M. A., Gotsopoulos, H., Petocz, P., & Cistulli, P. A. (2002). Effect of Vertical Dimension on Efficacy of Oral Appliance Therapy in Obstructive Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200204-342oc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.