Optimal High-Frequency Oscillatory Ventilation Settings by Nonlinear Lung Mechanics Analysis
The DOI matches its Crossref record.
Abstract
Use of nontidal high-frequency oscillatory ventilation (HFOV) while the lungs are expanded by an imposed airway pressure (P(aw)) in neonates is increasingly based on evidence of decreased risk of lung injury. However, an objective method to optimize P(aw) is lacking. We measured lung volume changes (deltaV(L)[t]) via respiratory inductance plethysmography over a range of P(aw) settings in five piglets before and after lung lavage. These multiple deltaV(L)(t) were then simultaneously fit by an exponential rise to maximum model, deltaV(L)(t, P(aw)) = deltaV(L,max). (1 - e(-(t/tau))), where deltaV(L,max) was a sigmoidal function of P(aw) and tau varied with lung volume. Postlavage, the effective compliance (C(EFF) = deltaV(L,max)/P(aw)) was generally decreased, whereas tau increased, indicating a slower paced volume recruitment. Model-derived C(EFF)-deltaV(L,max) relationships were altered substantially after lavage and were sigmoidal with a bell-shaped derivative function. The maximum of its derivative corresponded to a favorable (or optimal) deltaV(L)/P(aw) where the maximal increase in compliance is achieved. In conclusion, C(EFF)-deltaV(L,max) data available from respiratory inductance plethysmography provided important insight to changes in lung mechanics. These also provided a basis of an objective method (1) to optimize P(aw) during HFOV and (2) to assess the efficacy of treatments and progression/regression of underlying disease in neonates managed with HFOV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Drager, L. F., Togeiro, S. M., Polotsky, V. Y., & Lorenzi-Filho, G. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.045 · Cited by 886
Influence of Obstructive Sleep Apnea on Mortality in Patients With Heart Failure
Wang, H., Parker, J. D., Newton, G. E., Floras, J. S., Mak, S., Chiu, K.-L., Ruttanaumpawan, P., Tomlinson, G., & Bradley, T. D. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.046 · Cited by 616
Sleep Apnea and Heart Failure: Part I: Obstructive Sleep Apnea
Bradley, T. D., & Floras, J. S. (2003) · Circulation · doi:10.1161/01.cir.0000061757.12581.15 · Cited by 554
Tamisier, R., Pépin, J. L., Rémy, J., Baguet, J. P., Taylor, J. A., Weiss, J. W., & Lévy, P. (2011) · European Respiratory Journal · doi:10.1183/09031936.00204209 · Cited by 323
Metadata
- Authors
- Habib, R. H., Pyon, K. H., & Courtney, S. E.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-10-01
- Volume
- 166
- Issue
- 7
- Pages
- 950-953
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2062274765
- Cited by
- 46
- References
- 0
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.