Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 359

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?

Laghi, Franco, Cattapan, Steven E., Jubran, Amal, Parthasarathy, Sairam, Warshawsky, Paul, Choi, Yoon-Sub A., Tobin, Martin J.·2003·American Journal of Respiratory and Critical Care Medicine

Abstract

Because patients who fail a trial of weaning from mechanical ventilation experience a marked increase in respiratory load, we hypothesized that these patients develop diaphragmatic fatigue. Accordingly, we measured twitch transdiaphragmatic pressure using phrenic nerve stimulation in 11 weaning failure and 8 weaning success patients. Measurements were made before and 30 minutes after spontaneous breathing trials that lasted up to 60 minutes. Twitch transdiaphragmatic pressure was 8.9 +/- 2.2 cm H2O before the trials and 9.4 +/- 2.4 cm H2O after their completion in the weaning failure patients (p = 0.17); the corresponding values in the weaning success patients were 10.3 +/- 1.5 and 11.2 +/- 1.8 cm H2O (p = 0.18). Despite greater load (p = 0.04) and diaphragmatic effort (p = 0.01), the weaning failure patients did not develop low-frequency fatigue probably because of greater recruitment of rib cage and expiratory muscles (p = 0.004) and because clinical signs of distress mandating the reinstitution of mechanical ventilation arose before the development of fatigue. Twitch pressure revealed considerable diaphragmatic weakness in many weaning failure patients. In conclusion, in contrast to our hypothesis, weaning failure was not accompanied by low-frequency fatigue of the diaphragm, although many weaning failure patients displayed diaphragmatic weakness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200210-1246oc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 359

Metadata

Authors
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2003-01-15
Volume
167
Issue
2
Pages
120-127
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W1975384714
Cited by
359
References
1
FWCI
10.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm? https://app.cochat.ai/papers/10.1164/rccm.200210-1246oc
The paper
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J. (2003). Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm? American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200210-1246oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.