The DOI matches its Crossref record.
Randomized Trials Describing Lung Inflammation after Pleurodesis with Talc of Varying Particle Size
Abstract
We report two trials describing whether talc pleurodesis with a mean particle size of less than 15 microm ("mixed" talc) produces more lung and systemic inflammation than tetracycline or "graded" talc (most particles < 10 microm were removed). First, 20 patients with malignant effusions received tetracycline or mixed talc. Changes in lung and systemic inflammation from lung clearance scans, oxygen saturations, and C-reactive protein from baseline to 48 hours after pleurodesis were recorded. Lung inflammation (change in isotope clearance, talc -9.26, SD 14.3 vs. tetracycline 4.10, SD 13.8 minutes; difference = -13.4; 95% confidence interval [CI], -26.6 to -0.2; p = 0.05) and systemic inflammation (change in C-reactive protein, talc 198 SD 79.2 vs. tetracycline 74 SD 79.4 microg/L; difference = 124; 95% CI, 50 to 199; p = 0.004) were greater after talc. Second, 48 patients received mixed or graded talc, and gas exchange was assessed from changes in the alveolar-arterial oxygen gradient. Mixed talc worsened gas exchange (oxygen gradient change, mixed 2.17 SD 1.74 kPa, 16.3 13.1 mm Hg vs. graded 0.72 SD 2.46 kPa 5.4 18.5 mm Hg, difference = 1.45; 95% CI, 0.2 to 2.7; p = 0.03) and induced more systemic inflammation than graded talc. We conclude that the routine use of graded talc for pleurodesis would reduce the morbidity of this procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Management of spontaneous pneumothorax: British Thoracic Society pleural disease guideline 2010
MacDuff, A., Arnold, A., Harvey, J., & on behalf of the BTS Pleural Disease Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.136986 · Cited by 1,481
Management of a malignant pleural effusion: British Thoracic Society pleural disease guideline 2010
Roberts, M. E., Neville, E., Berrisford, R. G., Antunes, G., Ali, N. J., & on behalf of the BTS Pleural Disease Guideline Group (2010) · Thorax · doi:10.1136/thx.2010.136994 · Cited by 885
Local anaesthetic thoracoscopy: British Thoracic Society pleural disease guideline 2010
Rahman, N. M., Ali, N. J., Brown, G., Chapman, S. J., Davies, R. J. O., Downer, N. J., Gleeson, F. V., Howes, T. Q., Treasure, T., Singh, S., et al. (2010) · Thorax · doi:10.1136/thx.2010.137018 · Cited by 392
Self-citationERS task force statement: diagnosis and treatment of primary spontaneous pneumothorax
Tschopp, J.-M., Bintcliffe, O., Astoul, P., Canalis, E., Driesen, P., Janssen, J., Krasnik, M., Maskell, N., Van Schil, P., Tonia, T., et al. (2015) · European Respiratory Journal · doi:10.1183/09031936.00219214 · Cited by 368
Self-citationSafety of pleurodesis with talc poudrage in malignant pleural effusion: a prospective cohort study
Janssen, J. P., Collier, G., Astoul, P., Tassi, G. F., Noppen, M., Rodriguez-Panadero, F., Loddenkemper, R., Herth, F. J., Gasparini, S., Marquette, C. H., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60708-9 · Cited by 332
Metadata
- Authors
- Maskell, N. A., Lee, Y. C. G., Gleeson, F. V., Hedley, E. L., Pengelly, G., & Davies, R. J. O.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-08-15
- Volume
- 170
- Issue
- 4
- Pages
- 377-382
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2088170617
- Cited by
- 250
- References
- 0
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Randomized Trials Describing Lung Inflammation after Pleurodesis with Talc of Varying Particle Size. https://app.cochat.ai/papers/10.1164/rccm.200311-1579oc
- The paper
- Maskell, N. A., Lee, Y. C. G., Gleeson, F. V., Hedley, E. L., Pengelly, G., & Davies, R. J. O. (2004). Randomized Trials Describing Lung Inflammation after Pleurodesis with Talc of Varying Particle Size. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200311-1579oc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.