Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Six-Minute Walk, Maximal Exercise Tests: Reproducibility in Fibrotic Interstitial Pneumonia

Eaton, Tam, Young, Pam, Milne, David, Wells, Athol U. · 2005 · American Journal of Respiratory and Critical Care Medicine

Abstract

Resting pulmonary function and exercise variables are widely used to stage and monitor idiopathic interstitial pneumonia (IIP). However, the variability of exercise data (maximal exercise and the 6-minute walk test) has not been evaluated definitively. We have prospectively quantified the reproducibility of resting and exercise functional data in fibrotic IIP (idiopathic pulmonary fibrosis, fibrotic nonspecific interstitial pneumonia) and have evaluated interrelationships between variables. Thirty consecutive patients with fibrotic IIP underwent serial resting pulmonary function tests, 6-minute walk (n = 29), and maximal exercise (n = 24) at an interval of 1 week, with all testing performed in accordance with American Thoracic Society standards. Within-subject reproducibility was excellent for 6-minute walk distance (SD/mean = 4.2%) and clinically acceptable for resting pulmonary function indices and VO(2)max on maximal exercise testing. However, the amplitude of oxygen desaturation at the end of exercise was poorly reproducible in both 6-minute walk and maximal exercise testing (SD/mean > 25%). There was a highly significant relationship between VO2max on maximal exercise testing and 6-minute walk distance (r(s) = 0.78, p < 0.0001). In fibrotic IIP, the excellent reproducibility of the 6-minute walk distance is a major advantage in routine staging and monitoring, whereas maximal exercise variables are poorly reproducible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200405-578oc

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 274

Metadata

Authors
Eaton, T., Young, P., Milne, D., & Wells, A. U.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2005-05-15
Volume
171
Issue
10
Pages
1150-1157
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2150824191
Cited by
274
References
42
FWCI
12.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Six-Minute Walk, Maximal Exercise Tests: Reproducibility in Fibrotic Interstitial Pneumonia. https://app.cochat.ai/papers/10.1164/rccm.200405-578oc
The paper
Eaton, T., Young, P., Milne, D., & Wells, A. U. (2005). Six-Minute Walk, Maximal Exercise Tests: Reproducibility in Fibrotic Interstitial Pneumonia. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200405-578oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.