CoChat

A Randomized Double-Blind Trial of Iseganan in Prevention of Ventilator-associated Pneumonia

Open access
Kollef, Marin, Pittet, Didier, Sánchez García, Miguel, Chastre, Jean, Fagon, Jean-Yves, Bonten, Marc, Hyzy, Robert, Fleming, Thomas R., Fuchs, Henry, Bellm, Lisa, Mercat, Alain, Mañez, Rafael, Martínez, Antonio, Eggimann, Philippe, Daguerre, Martín · 2006 · American Journal of Respiratory and Critical Care Medicine
Cited by 122

The DOI matches its Crossref record.

Abstract

RATIONALE: Iseganan, an antimicrobial peptide, is active against aerobic and anaerobic gram-positive and gram-negative bacteria as well as fungi and yeasts. The drug has shown little resistance in vitro and to be safe and well tolerated in 800 patients with cancer treated for up to 6 wk. OBJECTIVES: To determine the efficacy of iseganan for the prevention of ventilator-associated pneumonia (VAP). METHODS: Mechanically ventilated patients in the United States and Europe were randomized to oral topical iseganan or placebo (1:1) and treated six times per day while intubated for up to 14 d. Patients were eligible if randomized within 24 h of intubation and estimated to survive and remain mechanically ventilated for 48 h or more. The primary efficacy endpoint of the study was VAP measured among survivors at Day 14. MEASUREMENTS AND MAIN RESULTS: A total of 709 patients were randomized and received at least one dose of study drug. The two groups were comparable at baseline except iseganan-treated patients were, on average, 3 yr older. The rate of VAP among survivors at Day 14 was 16% (45/282) in patients treated with iseganan and 20% (57/284) in those treated with placebo (p = 0.145). Mortality at Day 14 was 22.1% (80/362) in the iseganan group compared with 18.2% (63/347) in the placebo group (p = 0.206). No pattern of excess adverse events in the iseganan group compared with placebo was observed. CONCLUSIONS: Iseganan is not effective in improving outcome in patients on prolonged mechanical ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200504-656oc

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Kollef, M., Pittet, D., Sánchez García, M., Chastre, J., Fagon, J.-Y., Bonten, M., Hyzy, R., Fleming, T. R., Fuchs, H., Bellm, L., Mercat, A., Mañez, R., Martínez, A., Eggimann, P., & Daguerre, M.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2006-01-01
Volume
173
Issue
1
Pages
91-97
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2134586575
Cited by
122
References
0
FWCI
6.15
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Randomized Double-Blind Trial of Iseganan in Prevention of Ventilator-associated Pneumonia. https://app.cochat.ai/papers/10.1164/rccm.200504-656oc
The paper
Kollef, M., Pittet, D., Sánchez García, M., Chastre, J., Fagon, J.-Y., Bonten, M., Hyzy, R., Fleming, T. R., Fuchs, H., Bellm, L., Mercat, A., Mañez, R., Martínez, A., Eggimann, P., & Daguerre, M. (2006). A Randomized Double-Blind Trial of Iseganan in Prevention of Ventilator-associated Pneumonia. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200504-656oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.