Test Variability of the QuantiFERON-TB Gold In-Tube Assay in Clinical Practice

Open access
Metcalfe, John Z., Cattamanchi, Adithya, McCulloch, Charles E., Lew, Justin D., Ha, Ngan P., Graviss, Edward A. · 2013 · American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Although IFN-γ release assays (IGRAs) are widely used to screen for Mycobacterium tuberculosis infection in high-income countries, published data on repeatability are limited. OBJECTIVES: To determine IGRA repeatability. METHODS: The study population included consecutive patients referred to The Methodist Hospital (Houston, TX) between August 1, 2010 and July 31, 2011 for latent tuberculosis (TB) infection screening with an IGRA (QuantiFERON-TB Gold In-Tube; Cellestis, Carnegie, Australia). We performed multiple IGRA tests using leftover stimulated plasma according to a prospectively formulated quality control protocol. We analyzed agreement in interpretation of test results classified according to manufacturer-recommended criteria and repeatability of quantitative TB response. MEASUREMENTS AND MAIN RESULTS: During the study period, 1,086 test results were obtained from 543 subjects. Per the manufacturer's cut-point, the result of the second test was discordant from that of the first in 28 (8%) of 366 patients with valid test results, including 13 with an initial negative result and 15 with an initial positive result. Although agreement between repeat test results was high (κ = 0.84; 95% confidence interval, 0.79-0.90), the normal expected range of within-subject variability in TB response on retesting included differences of ± 0.60 IU/ml for all individuals (coefficient of variation, 14%), and ± 0.24 IU/ml (coefficient of variation, 27%) for individuals whose initial TB response was between 0.25 and 0.80 IU/ml. CONCLUSIONS: There is substantial variability in TB response when IGRAs are repeated using the same patient sample. IGRA results should be interpreted cautiously when TB response is near interpretation cut-points.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201203-0430oc

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 191

Metadata

Authors
Metcalfe, J. Z., Cattamanchi, A., McCulloch, C. E., Lew, J. D., Ha, N. P., & Graviss, E. A.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2013-01-15
Volume
187
Issue
2
Pages
206-211
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2166932611
Cited by
191
References
2
FWCI
15.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Test Variability of the QuantiFERON-TB Gold In-Tube Assay in Clinical Practice. https://app.cochat.ai/papers/10.1164/rccm.201203-0430oc
The paper
Metcalfe, J. Z., Cattamanchi, A., McCulloch, C. E., Lew, J. D., Ha, N. P., & Graviss, E. A. (2013). Test Variability of the QuantiFERON-TB Gold In-Tube Assay in Clinical Practice. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201203-0430oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.