Electronic Implementation of a Novel Surveillance Paradigm for Ventilator-associated Events. Feasibility and Validation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
RATIONALE: Accurate surveillance of ventilator-associated pneumonia (VAP) is hampered by subjective diagnostic criteria. A novel surveillance paradigm for ventilator-associated events (VAEs) was introduced. OBJECTIVES: To determine the validity of surveillance using the new VAE algorithm. METHODS: Prospective cohort study in two Dutch academic medical centers (2011-2012). VAE surveillance was electronically implemented and included assessment of (infection-related) ventilator-associated conditions (VAC, IVAC) and VAP. Concordance with ongoing prospective VAP surveillance was assessed, along with clinical diagnoses underlying VAEs and associated mortality of all conditions. Consequences of minor differences in electronic VAE implementation were evaluated. MEASUREMENTS AND MAIN RESULTS: The study included 2,080 patients with 2,296 admissions. Incidences of VAC, IVAC, VAE-VAP, and VAP according to prospective surveillance were 10.0, 4.2, 3.2, and 8.0 per 1000 ventilation days, respectively. The VAE algorithm detected at most 32% of the patients with VAP identified by prospective surveillance. VAC signals were most often caused by volume overload and infections, but not necessarily VAP. Subdistribution hazards for mortality were 3.9 (95% confidence interval, 2.9-5.3) for VAC, 2.5 (1.5-4.1) for IVAC, 2.0 (1.1-3.6) for VAE-VAP, and 7.2 (5.1-10.3) for VAP identified by prospective surveillance. In sensitivity analyses, mortality estimates varied considerably after minor differences in electronic algorithm implementation. CONCLUSIONS: Concordance between the novel VAE algorithm and VAP was poor. Incidence and associated mortality of VAE were susceptible to small differences in electronic implementation. More studies are needed to characterize the clinical entities underlying VAE and to ensure comparability of rates from different institutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Proportional Hazards Model for the Subdistribution of a Competing Risk
Fine, J. P., & Gray, R. J. (1999) · Journal of the American Statistical Association · doi:10.1080/01621459.1999.10474144 · Cited by 14,290
Cited by
Broad defects in the energy metabolism of leukocytes underlie immunoparalysis in sepsis
Cheng, S.-C., Scicluna, B. P., Arts, R. J. W., Gresnigt, M. S., Lachmandas, E., Giamarellos-Bourboulis, E. J., Kox, M., Manjeri, G. R., Wagenaars, J. A. L., Cremer, O. L., et al. (2016) · Nature Immunology · doi:10.1038/ni.3398 · Cited by 637
van Vught, L. A., Klein Klouwenberg, P. M. C., Spitoni, C., Scicluna, B. P., Wiewel, M. A., Horn, J., Schultz, M. J., Nürnberg, P., Bonten, M. J. M., Cremer, O. L., et al. (2016) · JAMA · doi:10.1001/jama.2016.2691 · Cited by 528
Self-citationStrategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals: 2014 Update
Klompas, M., Branson, R., Eichenwald, E. C., Greene, L. R., Howell, M. D., Lee, G., Magill, S. S., Maragakis, L. L., Priebe, G. P., Speck, K., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/677144 · Cited by 427
Klompas, M., Branson, R., Cawcutt, K., Crist, M., Eichenwald, E. C., Greene, L. R., Lee, G., Maragakis, L. L., Powell, K., Priebe, G. P., et al. (2022) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2022.88 · Cited by 402
Pugh, R., Grant, C., Cooke, R. P., & Dempsey, G. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007577.pub3 · Cited by 289
Metadata
- Authors
- Klein Klouwenberg, P. M. C., van Mourik, M. S. M., Ong, D. S. Y., Horn, J., Schultz, M. J., Cremer, O. L., & Bonten, M. J. M.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-04-15
- Volume
- 189
- Issue
- 8
- Pages
- 947-955
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2136141163
- Cited by
- 153
- References
- 1
- FWCI
- 21.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.