Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 223

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Randomized Trial of Apneic Oxygenation during Endotracheal Intubation of the Critically Ill

Open access
Semler, Matthew W., Janz, David R., Lentz, Robert J., Matthews, Daniel T., Norman, Brett C., Assad, Tufik R., Keriwala, Raj D., Ferrell, Benjamin A., Noto, Michael J., McKown, Andrew C., Kocurek, Emily G., Warren, Melissa A., Huerta, Luis E., Rice, Todd W. · 2016 · American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Hypoxemia is common during endotracheal intubation of critically ill patients and may predispose to cardiac arrest and death. Administration of supplemental oxygen during laryngoscopy (apneic oxygenation) may prevent hypoxemia. OBJECTIVES: To determine if apneic oxygenation increases the lowest arterial oxygen saturation experienced by patients undergoing endotracheal intubation in the intensive care unit. METHODS: This was a randomized, open-label, pragmatic trial in which 150 adults undergoing endotracheal intubation in a medical intensive care unit were randomized to receive 15 L/min of 100% oxygen via high-flow nasal cannula during laryngoscopy (apneic oxygenation) or no supplemental oxygen during laryngoscopy (usual care). The primary outcome was lowest arterial oxygen saturation between induction and 2 minutes after completion of endotracheal intubation. MEASUREMENTS AND MAIN RESULTS: Median lowest arterial oxygen saturation was 92% with apneic oxygenation versus 90% with usual care (95% confidence interval for the difference, -1.6 to 7.4%; P = 0.16). There was no difference between apneic oxygenation and usual care in incidence of oxygen saturation less than 90% (44.7 vs. 47.2%; P = 0.87), oxygen saturation less than 80% (15.8 vs. 25.0%; P = 0.22), or decrease in oxygen saturation greater than 3% (53.9 vs. 55.6%; P = 0.87). Duration of mechanical ventilation, intensive care unit length of stay, and in-hospital mortality were similar between study groups. CONCLUSIONS: Apneic oxygenation does not seem to increase lowest arterial oxygen saturation during endotracheal intubation of critically ill patients compared with usual care. These findings do not support routine use of apneic oxygenation during endotracheal intubation of critically ill adults. Clinical trial registered with www.clinicaltrials.gov (NCT 02051816).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201507-1294oc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 223

Metadata

Authors
Semler, M. W., Janz, D. R., Lentz, R. J., Matthews, D. T., Norman, B. C., Assad, T. R., Keriwala, R. D., Ferrell, B. A., Noto, M. J., McKown, A. C., Kocurek, E. G., Warren, M. A., Huerta, L. E., & Rice, T. W.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2016-02-01
Volume
193
Issue
3
Pages
273-280
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W1931489128
Cited by
223
References
1
FWCI
36.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Trial of Apneic Oxygenation during Endotracheal Intubation of the Critically Ill. https://app.cochat.ai/papers/10.1164/rccm.201507-1294oc
The paper
Semler, M. W., Janz, D. R., Lentz, R. J., Matthews, D. T., Norman, B. C., Assad, T. R., Keriwala, R. D., Ferrell, B. A., Noto, M. J., McKown, A. C., Kocurek, E. G., Warren, M. A., Huerta, L. E., & Rice, T. W. (2016). Randomized Trial of Apneic Oxygenation during Endotracheal Intubation of the Critically Ill. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201507-1294oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.