Measuring Loop Gain via Home Sleep Testing in Patients with Obstructive Sleep Apnea
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
To the Editor:Nonanatomical traits contribute to obstructive sleep apnea (OSA) in certain individuals (1) and can predict response to therapies beyond continuous positive airway pressure (CPAP) (2, 3).Unstable ventilatory control (high loop gain) is one such trait that is useful for personalizing treatment (4).Measuring loop gain has traditionally required the use of specialized equipment and laborintensive techniques (5); however, recently developed methods can determine loop gain from polysomnography (PSG) using a modelfitting technique (6).Because clinical testing for OSA is shifting to home sleep testing (HST), our aim in this study was to determine whether we could estimate loop gain using this limited dataset, which might facilitate personalized OSA treatment in clinical practice.Subjects with untreated OSA (apnea-hypopnea index [AHI] > 5/h) who underwent both PSG and HST within a 3-month period were included in the study.The research was approved by the institutional review board (#141272 and #150465), and the subjects provided written informed consent.The exclusion criteria were use of sedatives, hypnotics, or narcotics, ongoing OSA treatment, and/or prior airway surgery.In-laboratory attended PSG was performed in the standard fashion with the subjects supine.HST was performed with a type III device (ApneaLink Plus/Air; ResMed).Results were scored using American Academy of Sleep Medicine Chicago criteria (3% desaturation) by a technologist blinded to outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“It may be possible to quantify loop gain directly from inlab or home sleep studies.369–371”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [369]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypercapnic ventilatory response in sleeping adults.
Douglas, N. J., White, D. P., Weil, J. V., Pickett, C. K., & Zwillich, C. W. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.758 · Cited by 371 · cited 2×
“Without sleep-stage data, events that presumably occurred during REM sleep were included in the HST measures, biasing the loop gain downward (8).”
BackgroundMethodQuantifying the ventilatory control contribution to sleep apnoea using polysomnography
Terrill, P. I., Edwards, B. A., Nemati, S., Butler, J. P., Owens, R. L., Eckert, D. J., White, D. P., Malhotra, A., Wellman, A., & Sands, S. A. (2015) · European Respiratory Journal · doi:10.1183/09031936.00062914 · Cited by 289 · cited 10×
“The dynamic loop gain is assessed at a frequency of one cycle per minute (LG1) based on the kinetics of OSA (6, 7).”
MethodSelf-citationEdwards, B. A., Andara, C., Landry, S., Sands, S. A., Joosten, S. A., Owens, R. L., White, D. P., Hamilton, G. S., & Wellman, A. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201601-0099oc · Cited by 228 · cited 4×
“To the Editor: Nonanatomical traits contribute to obstructive sleep apnea (OSA) in certain individuals (1) and can predict response to therapies beyond continuous positive airway pressure (CPAP) (2, 3).”
BackgroundSelf-citationA simplified method for determining phenotypic traits in patients with obstructive sleep apnea
Wellman, A., Edwards, B. A., Sands, S. A., Owens, R. L., Nemati, S., Butler, J., Passaglia, C. L., Jackson, A. C., Malhotra, A., & White, D. P. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00747.2012 · Cited by 222 · cited 1×
“Measuring loop gain has traditionally required the use of specialized equipment and laborintensive techniques (5); however, recently developed methods can determine loop gain from polysomnography (PSG) using a modelfitting technique (6).”
MethodSelf-citationOwens, R. L., Edwards, B. A., Eckert, D. J., Jordan, A. S., Sands, S. A., Malhotra, A., White, D. P., Loring, S. H., Butler, J. P., & Wellman, A. (2015) · SLEEP · doi:10.5665/sleep.4750 · Cited by 138
Self-citationThe Effect of Body Position on Physiological Factors that Contribute to Obstructive Sleep Apnea
Joosten, S. A., Edwards, B. A., Wellman, A., Turton, A., Skuza, E. M., Berger, P. J., & Hamilton, G. S. (2015) · Sleep · doi:10.5665/sleep.4992 · Cited by 118
Self-citationHorner, R. L., Rivera, M. P., Kozar, L. F., & Phillipson, E. A. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00881.x · Cited by 73 · cited 1×
“Arousal may transiently increase the overall ventilatory drive independently of the chemical drive as a brief transition to waking (8) or as a distinct ventilatory component akin to a startle response (9).”
BackgroundPhysiology-Based Modeling May Predict Surgical Treatment Outcome for Obstructive Sleep Apnea
Li, Y., Ye, J., Han, D., Cao, X., Ding, X., Zhang, Y., Xu, W., Orr, J., Jen, R., Sands, S., et al. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6716 · Cited by 64 · cited 4×
“To the Editor: Nonanatomical traits contribute to obstructive sleep apnea (OSA) in certain individuals (1) and can predict response to therapies beyond continuous positive airway pressure (CPAP) (2, 3).”
BackgroundSelf-citationObstructive sleep apnoea: longer respiratory event lengths in patients with heart failure
Efken, C., Bitter, T., Prib, N., Horstkotte, D., & Oldenburg, O. (2012) · European Respiratory Journal · doi:10.1183/09031936.00082212 · Cited by 45 · cited 7×
“The dynamic loop gain is assessed at a frequency of one cycle per minute (LG1) based on the kinetics of OSA (6, 7).”
MethodInfluentialCrossTalk opposing view: Loop gain is not a consequence of obstructive sleep apnoea
Orr, J. E., Edwards, B. A., & Malhotra, A. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2014.271841 · Cited by 25 · cited 1×
“Unstable ventilatory control (high loop gain) is one such trait that is useful for personalizing treatment (4).”
BackgroundSelf-citation
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Self-citationEndotypes and phenotypes in obstructive sleep apnea
Malhotra, A., Mesarwi, O., Pepin, J.-L., & Owens, R. L. (2020) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0000000000000724 · Cited by 169
Self-citationDutta, R., Delaney, G. W., Toson, B., Jordan, A. S., White, D. P., Wellman, A., & Eckert, D. J. (2020) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202001-064oc · Cited by 87
Precision Medicine for Obstructive Sleep Apnea
Light, M. P., Owens, R. L., Schmickl, C. N., & Malhotra, A. (2019) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2019.05.005 · Cited by 54
Self-citationTolbert, T. M., Schmickl, C. N., Gell, L. K., Keenan, B. T., Mazzotti, D. R., de Beeck, S. O., Osman, A. M., Peña-Orbea, C., Sands, S. A., Sofer, T., et al. (2025) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202507-1574st · Cited by 53
Self-citation
Metadata
- Authors
- Orr, J. E., Sands, S. A., Edwards, B. A., Deyoung, P. N., Deacon, N., Jen, R., Li, Y., Owens, R. L., & Malhotra, A.
- Affiliations
- University of California San Diego (US)
- Brigham and Women's Hospital (US)
- Monash University (AU)
- ORCID
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-05
- Volume
- 197
- Issue
- 10
- Pages
- 1353-1355
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- PMC
- PMC5955058
- OpenAlex
- W2775410145
- Semantic Scholar
- 55618564f6580aeb37a54d6fb89ff3b445942ff9
- Cited by
- 29
- References
- 10
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 7 · 2022: 6 · 2021: 1 · 2020: 5 · 2019: 3 · 2018: 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Heart, Lung, and Blood Institute (F32HL131306, R01HL081823, T32HL134632, R21HL121794, R01HL085188, K24HL132105, R01HL119201)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- obstructive sleep apnea, loop gain, home sleep testing, ventilation control, personalized treatment, polysomnography, apnea-hypopnea index
- MeSH terms
- Adult, Female, Humans, Male, Middle Aged, Oxygen Consumption, Polysomnography, Sleep Apnea, Obstructive, Self Report
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring Loop Gain via Home Sleep Testing in Patients with Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.201707-1357le
- The paper
- Orr, J. E., Sands, S. A., Edwards, B. A., Deyoung, P. N., Deacon, N., Jen, R., Li, Y., Owens, R. L., & Malhotra, A. (2018). Measuring Loop Gain via Home Sleep Testing in Patients with Obstructive Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201707-1357le
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.