Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 810

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

An Index Combining Respiratory Rate and Oxygenation to Predict Outcome of Nasal High-Flow Therapy

Roca, Oriol, Caralt, Berta, Messika, Jonathan, Samper, Manuel, Sztrymf, Benjamin, Hernández, Gonzalo, García-de-Acilu, Marina, Frat, Jean-Pierre, Masclans, Joan R., Ricard, Jean-Damien·2019·American Journal of Respiratory and Critical Care Medicine

Abstract

Abstract Rationale One important concern during high-flow nasal cannula (HFNC) therapy in patients with acute hypoxemic respiratory failure is to not delay intubation. Objectives To validate the diagnostic accuracy of an index (termed ROX and defined as the ratio of oxygen saturation as measured by pulse oximetry/FiO2 to respiratory rate) for determining HFNC outcome (need or not for intubation). Methods This was a 2-year multicenter prospective observational cohort study including patients with pneumonia treated with HFNC. Identification was through Cox proportional hazards modeling of ROX association with HFNC outcome. The most specific cutoff of the ROX index to predict HFNC failure and success was assessed. Measurements and Main Results Among the 191 patients treated with HFNC in the validation cohort, 68 (35.6%) required intubation. The prediction accuracy of the ROX index increased over time (area under the receiver operating characteristic curve: 2 h, 0.679; 6 h, 0.703; 12 h, 0.759). ROX greater than or equal to 4.88 measured at 2 (hazard ratio, 0.434; 95% confidence interval, 0.264–0.715; P = 0.001), 6 (hazard ratio, 0.304; 95% confidence interval, 0.182–0.509; P < 0.001), or 12 hours (hazard ratio, 0.291; 95% confidence interval, 0.161–0.524; P < 0.001) after HFNC initiation was consistently associated with a lower risk for intubation. A ROX less than 2.85, less than 3.47, and less than 3.85 at 2, 6, and 12 hours of HFNC initiation, respectively, were predictors of HFNC failure. Patients who failed presented a lower increase in the values of the ROX index over the 12 hours. Among components of the index, oxygen saturation as measured by pulse oximetry/FiO2 had a greater weight than respiratory rate. Conclusions In patients with pneumonia with acute respiratory failure treated with HFNC, ROX is an index that can help identify those patients with low and those with high risk for intubation. Clinical trial registered with www.clinicaltrials.gov (NCT 02845128).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201803-0589oc

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 810

Metadata

Authors
Roca, O., Caralt, B., Messika, J., Samper, M., Sztrymf, B., Hernández, G., García-de-Acilu, M., Frat, J.-P., Masclans, J. R., & Ricard, J.-D.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2019-06-01
Volume
199
Issue
11
Pages
1368-1376
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2906476728
Cited by
810
References
26
FWCI
43.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Index Combining Respiratory Rate and Oxygenation to Predict Outcome of Nasal High-Flow Therapy. https://app.cochat.ai/papers/10.1164/rccm.201803-0589oc
The paper
Roca, O., Caralt, B., Messika, J., Samper, M., Sztrymf, B., Hernández, G., García-de-Acilu, M., Frat, J.-P., Masclans, J. R., & Ricard, J.-D. (2019). An Index Combining Respiratory Rate and Oxygenation to Predict Outcome of Nasal High-Flow Therapy. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201803-0589oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.