Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 223

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Airway Occlusion Pressure As an Estimate of Respiratory Drive and Inspiratory Effort during Assisted Ventilation

Telias, Irene, Junhasavasdikul, Detajin, Rittayamai, Nuttapol, Piquilloud, Lise, Chen, Lu, Ferguson, Niall D., Goligher, Ewan C., Brochard, Laurent · 2020 · American Journal of Respiratory and Critical Care Medicine

Abstract

Abstract Rationale Monitoring and controlling respiratory drive and effort may help to minimize lung and diaphragm injury. Airway occlusion pressure (P0.1) is a noninvasive measure of respiratory drive. Objectives To determine 1) the validity of “ventilator” P0.1 (P0.1vent) displayed on the screen as a measure of drive, 2) the ability of P0.1 to detect potentially injurious levels of effort, and 3) how P0.1vent displayed by different ventilators compares to a “reference” P0.1 (P0.1ref) measured from airway pressure recording during an occlusion. Methods Analysis of three studies in patients, one in healthy subjects, under assisted ventilation, and a bench study with six ventilators. P0.1vent was validated against measures of drive (electrical activity of the diaphragm and muscular pressure over time) and P0.1ref. Performance of P0.1ref and P0.1vent to detect predefined potentially injurious effort was tested using derivation and validation datasets using esophageal pressure–time product as the reference standard. Measurements and Main Results P0.1vent correlated well with measures of drive and with the esophageal pressure–time product (within-subjects R2 = 0.8). P0.1ref >3.5 cm H2O was 80% sensitive and 77% specific for detecting high effort (≥200 cm H2O ⋅ s ⋅ min−1); P0.1ref ≤1.0 cm H2O was 100% sensitive and 92% specific for low effort (≤50 cm H2O ⋅ s ⋅ min−1). The area under the receiver operating characteristics curve for P0.1vent to detect potentially high and low effort were 0.81 and 0.92, respectively. Bench experiments showed a low mean bias for P0.1vent compared with P0.1ref for most ventilators but precision varied; in patients, precision was lower. Ventilators estimating P0.1vent without occlusions could underestimate P0.1ref. Conclusions P0.1 is a reliable bedside tool to assess respiratory drive and detect potentially injurious inspiratory effort.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201907-1425oc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 223

Metadata

Authors
Telias, I., Junhasavasdikul, D., Rittayamai, N., Piquilloud, L., Chen, L., Ferguson, N. D., Goligher, E. C., & Brochard, L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2020-05-01
Volume
201
Issue
9
Pages
1086-1098
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W3006991244
Cited by
223
References
1
FWCI
11.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Airway Occlusion Pressure As an Estimate of Respiratory Drive and Inspiratory Effort during Assisted Ventilation. https://app.cochat.ai/papers/10.1164/rccm.201907-1425oc
The paper
Telias, I., Junhasavasdikul, D., Rittayamai, N., Piquilloud, L., Chen, L., Ferguson, N. D., Goligher, E. C., & Brochard, L. (2020). Airway Occlusion Pressure As an Estimate of Respiratory Drive and Inspiratory Effort during Assisted Ventilation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201907-1425oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.