COVID-19 Does Not Lead to a “Typical” Acute Respiratory Distress Syndrome

Open access
Gattinoni, Luciano, Coppola, Silvia, Cressoni, Massimo, Busana, Mattia, Rossi, Sandra, Chiumello, Davide·2020·American Journal of Respiratory and Critical Care Medicine

Abstract

ARDS with COVID-19.An intermediate VT (7-8 ml/kg PBW) ventilation strategy was applied to the first four patients to increase pulmonary efficiency to eliminate CO 2 , and this was used in the next four patients.Gas exchange consists of oxygenation and ventilation.Oxygenation is quantified by the Pa O 2 /FI O 2 ratio, and this method has gained wide acceptance, particularly since publication of the Berlin definition of ARDS (7).However, the Berlin definition does not include additional pathophysiological information about ARDS, such as alveolar ventilation, as measured by pulmonary dead space, which is an important predictor of outcome (8).Increased pulmonary dead space reflects the inefficiency of the lungs to eliminate CO 2 , which may lead to hypercapnia.In our patients with ARDS with COVID-19, hypercapnia was common at ICU admission with low VT ventilation.Assuming the anatomic portion of dead space is constant, increasing VT with constant respiratory rate would effectively increase alveolar ventilation.Any such increase in VT would decrease Pa CO 2 , which would be captured by VR (6).VR, a novel method to monitor ventilatory adequacy at the bedside (4-6), was very high in our patients, reflecting increased pulmonary dead space and inadequacy of ventilation.With an acceptable plateau pressure and driving pressure, titration of VT was performed.Pa CO 2 and VR were significantly decreased when an intermediate VT (7-8 ml/kg PBW) was applied.We suggest that intermediate VT (7-8 ml/kg PBW) is recommended for such patients.Therefore, low VT may not be the best approach for all patients with ARDS, particularly those with a less severe decrease in respiratory system compliance and inadequacy of ventilation.In summary, we found that hypercapnia was common in patients with COVID-19-associated ARDS while using low VT ventilation.VR was increased in these patients, which reflected increased pulmonary dead space and inadequacy of ventilation.An intermediate VT was used to correct hypercapnia efficiently, while not excessively increasing driving pressure.Clinicians must have a high index of suspicion for increased pulmonary dead space when patients with COVID-19-related ARDS present with hypercapnia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.202003-0817le

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 1,396

Metadata

Authors
Gattinoni, L., Coppola, S., Cressoni, M., Busana, M., Rossi, S., & Chiumello, D.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2020-05-15
Volume
201
Issue
10
Pages
1299-1300
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W3013176450
Cited by
1,396
References
1
FWCI
158.11
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: COVID-19 Does Not Lead to a “Typical” Acute Respiratory Distress Syndrome. https://app.cochat.ai/papers/10.1164/rccm.202003-0817le
The paper
Gattinoni, L., Coppola, S., Cressoni, M., Busana, M., Rossi, S., & Chiumello, D. (2020). COVID-19 Does Not Lead to a “Typical” Acute Respiratory Distress Syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.202003-0817le

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.