Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 433

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Ventilatory Variables and Mechanical Power in Patients with Acute Respiratory Distress Syndrome

Open access
Costa, Eduardo L. V., Slutsky, Arthur S., Brochard, Laurent J., Brower, Roy, Serpa-Neto, Ary, Cavalcanti, Alexandre B., Mercat, Alain, Meade, Maureen, Morais, Caio C. A., Goligher, Ewan, Carvalho, Carlos R. R., Amato, Marcelo B. P.·2021·American Journal of Respiratory and Critical Care Medicine

Abstract

Abstract Rationale Mortality in acute respiratory distress syndrome (ARDS) has decreased after the adoption of lung-protective strategies. Lower Vt, lower driving pressure (ΔP), lower respiratory rates (RR), and higher end-expiratory pressure have all been suggested as key components of lung protection strategies. A unifying theoretical explanation has been proposed that attributes lung injury to the energy transfer rate (mechanical power) from the ventilator to the patient, calculated from a combination of several ventilator variables. Objectives To assess the impact of mechanical power on mortality in patients with ARDS as compared with that of primary ventilator variables such as the ΔP, Vt, and RR. Methods We obtained data on ventilatory variables and mechanical power from a pooled database of patients with ARDS who had participated in six randomized clinical trials of protective mechanical ventilation and one large observational cohort of patients with ARDS. The primary outcome was mortality at 28 days or 60 days. Measurements and Main Results We included 4,549 patients (38% women; mean age, 55 ± 23 yr). The average mechanical power was 0.32 ± 0.14 J · min−1 · kg−1 of predicted body weight, the ΔP was 15.0 ± 5.8 cm H2O, and the RR was 25.7 ± 7.4 breaths/min. The driving pressure, RR, and mechanical power were significant predictors of mortality in adjusted analyses. The impact of the ΔP on mortality was four times as large as that of the RR. Conclusions Mechanical power was associated with mortality during controlled mechanical ventilation in ARDS, but a simpler model using only the ΔP and RR was equivalent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.202009-3467oc

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 433

Metadata

Authors
Costa, E. L. V., Slutsky, A. S., Brochard, L. J., Brower, R., Serpa-Neto, A., Cavalcanti, A. B., Mercat, A., Meade, M., Morais, C. C. A., Goligher, E., Carvalho, C. R. R., & Amato, M. B. P.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2021-08-01
Volume
204
Issue
3
Pages
303-311
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W3151258134
Cited by
433
References
24
FWCI
38.30
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ventilatory Variables and Mechanical Power in Patients with Acute Respiratory Distress Syndrome. https://app.cochat.ai/papers/10.1164/rccm.202009-3467oc
The paper
Costa, E. L. V., Slutsky, A. S., Brochard, L. J., Brower, R., Serpa-Neto, A., Cavalcanti, A. B., Mercat, A., Meade, M., Morais, C. C. A., Goligher, E., Carvalho, C. R. R., & Amato, M. B. P. (2021). Ventilatory Variables and Mechanical Power in Patients with Acute Respiratory Distress Syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.202009-3467oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.