Validation of Nasal Pressure for the Identification of Apneas/Hypopneas during Sleep
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The reference standard for identifying apneas and hypopneas is a pneumotachograph, but using this can disrupt sleep. Nasal airflow estimation by measuring nasal pressure via nasal prongs is better tolerated by patients. However, nasal pressure has not been validated, using an event-by-event analysis, for detecting apneas/hypopneas during sleep. Eleven patients undergoing polysomnography wore a nasal mask capable of measuring nasal airflow (via pneumotachograph) and nasal pressure simultaneously. Each study was screened for respiratory disturbances, and from these 550 were randomly selected and blindly scored as an apnea/hypopnea or no event each using the pneumotachograph, nasal pressure, square root nasal pressure, and respiratory inductance sum signals independently. Agreement was measured using Cohen's kappa statistic. Intermeasurement agreements between the pneumotachograph and nasal pressure, square root nasal pressure, and respiratory inductance plethysmography sum were 0.76, 0.73, and 0.50, respectively. Inter- and intrarater agreements were, respectively, 0.68 and 0.60 for the pneumotachograph, 0.66 and 0.82 for nasal pressure, 0.61 and 0.78 for square root nasal pressure, and 0.47 and 0.76 for respiratory inductance plethysmography sum. These results indicate that nasal pressure has excellent agreement compared with a pneumotachograph and very good inter-/intrarater agreement. Square root transformation of the nasal pressure signal does not improve these levels of agreement, indicating that it is unnecessary in routine clinical practice for scoring apneas/hypopneas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00025-4 · Cited by 555
Daytime Sleepiness and Hyperactivity in Children With Suspected Sleep-Disordered Breathing
Melendres, C. S., Lutz, J. M., Rubin, E. D., & Marcus, C. L. (2004) · Pediatrics · doi:10.1542/peds.2004-0730 · Cited by 381
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
Impaired Performance in Commercial Drivers
Pack, A. I., Maislin, G., Staley, B., Pack, F. M., Rogers, W. C., George, C. F. P., & Dinges, D. F. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200408-1146oc · Cited by 173
Metadata
- Authors
- Heitman, S. J., Atkar, R. S., Hajduk, E. A., Wanner, R. A., & Flemons, W. W.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-08-01
- Volume
- 166
- Issue
- 3
- Pages
- 386-391
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2128189145
- Cited by
- 82
- References
- 1
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Nasal Pressure for the Identification of Apneas/Hypopneas during Sleep. https://app.cochat.ai/papers/10.1164/rccm.2105085
- The paper
- Heitman, S. J., Atkar, R. S., Hajduk, E. A., Wanner, R. A., & Flemons, W. W. (2002). Validation of Nasal Pressure for the Identification of Apneas/Hypopneas during Sleep. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.2105085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.