Cited by 49

The DOI matches its Crossref record.

Alveolar Macrophage-Particle Relationships During Lung Clearance

Lehnert, Bruce E., Valdez, Yolanda E., Tietjen, Gary L.·1989·American Journal of Respiratory Cell and Molecular Biology

Abstract

Retention kinetics for insoluble particles that deposit in the lung oftentimes resemble a multicomponent process during alveolar clearance, with each component appearing to follow simple first-order kinetics. Inasmuch as alveolar macrophages (AM) are thought to play an important role in particle removal from the lung, a study was undertaken to examine particle-AM relationships during the clearance of particles to obtain information on potential AM mechanisms that could provide the underlying bases for the lung retention kinetics of the particles. Adult, Fischer 344 rats were intratracheally instilled with 1.6 × 107 (∼86 µg) polystyrene microspheres (∼2 µm diam). On Days 7, 14, 57, 85, and 176 thereafter, subgroups were killed, their lungs were lavaged, recovered cells (>95% AM) were counted, the frequency distribution of the particles among the AM was determined (e.g., zero, 1 to 2, 3 to 4 particles/AM), and the total numbers of particles lavaged were estimated. The lavaged lungs were solubilized, and unlavaged particles were also counted. The sums of the lavaged and unlavaged particles were used to estimate retained lung burdens at each postinstillation time. The lung retention data followed a pattern consistent with the sum of two negative exponential components, i.e., an earlier, more rapid component and a slower, longer term component. The rates at which the AM disappeared from a given particle category also were biphasic for AM that contained up to 14 microspheres. The rates of both the earlier and longer term components of such disappearance were found to increase with increasing AM burdens. Over an AM burden range of 1 to 10 microspheres, the proportion of AM that disappeared via rapid components also increased as the particle burden defining an AM category increased. At higher particle burdens, the proportion of AM that disappeared by an early component appeared to markedly diminish; an early component for AM disappearance was no longer resolvable for AM that contained >15 microspheres. The net effect of these phenomena was that retained lung burdens over time became progressively contained in AM with lesser burdens of particles. The results from this study suggest that the rate(s) of translocation of particle-containing AM from the lung during lung clearance may be related to their individual particulate burdens. These findings, however, are also consistent with a gradual redistribution of particles among the lung's AM population over time concurrent with AM removal from the lung. Regardless, the biphasic nature of the lung retention data qualitatively was generally evident for particle-containing AM as well.

Overview

Integrity signals

Registry

Crossref · 10.1165/ajrcmb/1.2.145

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

See all 49

Metadata

Authors
Lehnert, B. E., Valdez, Y. E., & Tietjen, G. L.
Venue
American Journal of Respiratory Cell and Molecular Biology
Published
1989-08-01
Volume
1
Issue
2
Pages
145-154
ISSN
  • 1044-1549
  • 1535-4989
Cited by
49
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Alveolar Macrophage-Particle Relationships During Lung Clearance. https://app.cochat.ai/papers/10.1165/ajrcmb/1.2.145
The paper
Lehnert, B. E., Valdez, Y. E., & Tietjen, G. L. (1989). Alveolar Macrophage-Particle Relationships During Lung Clearance. American Journal of Respiratory Cell and Molecular Biology. https://doi.org/10.1165/ajrcmb/1.2.145