Cited by 142

The DOI matches its Crossref record.

Estimates of L:M cone ratio from ERG flicker photometry and genetics

Carroll, J., Neitz, J., Neitz, M.·2002·Journal of Vision

Abstract

Estimates of L:M cone ratio for males with normal color vision were derived using the flicker-photometric electroretinogram (ERG). These were obtained by best fitting ERG spectral sensitivity functions to a weighted sum of long (L)- and middle (M)-wavelength-sensitive cone spectral absorption curves. Using the ERG, measurements can be made with extremely high precision, which leaves variation in the wavelength of maximal sensitivity (lambda(max)) of the cone photopigments as the major remaining source of inaccuracy in determining the ratio of cone contributions. Here that source of inaccuracy was largely eliminated through the use of individualized L-cone spectral absorption curves deduced from L-pigment gene sequences. The method was used on 62 normal males as part of an effort to obtain a true picture of how normal variations in L:M cone ratio are distributed. The percentage of L cones in the average eye was 65%L [where %L = 100 X L / (L+M)]. There were huge individual differences ranging from 28%-93%L, corresponding to more than a 30-fold range in L:M ratio (0.4-13). However, the most extreme values were relatively rare; 80% of the subjects fell within +/-15 %L of the mean, corresponding to a 4-fold range in L:M ratio (1-4). The method remedies major weaknesses inherent in earlier applications of flicker photometry to estimate cone ratio; however, it continues to depend on the assumption that the average L cone produces a response with an identical amplitude to that of the…

Overview

Integrity signals

Registry

Crossref · 10.1167/2.8.1

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

Metadata

Authors
Carroll, J., Neitz, J., & Neitz, M.
Venue
Journal of Vision
Published
2002-11-01
Volume
2
Issue
8
Pages
1-1
ISSN
1534-7362
Cited by
142
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review